Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

5R4GY

Directly heated full-wave high-vacuum rectifier for AC-operated equipment requiring substantial high-voltage DC output. It provides approximately 250 mA output with high peak inverse-voltage capability.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
5T
Socket code
IO
Base pins
8
Nominal heater
5 V / 2 A

Description

5R4GY is a Rectifier device. Full-wave power rectifier for AC-operated equipment requiring substantial DC output current.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
5T
Socket code
IO
Base pins
8
Nominal heater voltage
5 V
Nominal heater current
2 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

5T - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN1ISAIS — Internal Screen

EIA chart transcription; manufacturer corroboration pending

Unverified

EIA Base Connections, printed page 127, 5T

PIN2F—F — Filament

EIA chart transcription; manufacturer corroboration pending

Unverified

EIA Base Connections, printed page 127, 5T

PIN4P1AP — Plate (Anode)

EIA chart transcription; manufacturer corroboration pending; preserve source designation P1

Unverified

EIA Base Connections, printed page 127, 5T

PIN6P2AP — Plate (Anode)

EIA chart transcription; manufacturer corroboration pending; preserve source designation P2

Unverified

EIA Base Connections, printed page 127, 5T

PIN8F—F — Filament

EIA chart transcription; manufacturer corroboration pending

Unverified

EIA Base Connections, printed page 127, 5T

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
2800 V
Rectifier nominal output current
250 mA
Rectifier peak forward current
650 mA
Rectifier forward voltage drop
67 V

Published full-wave rectifier ratings promoted from the printed chart; supply-voltage and voltage-drop test conditions retained as parameters.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
2800 V
Rectifier nominal output current
250 mA
Rectifier peak forward current
650 mA
Rectifier forward voltage drop
67 V

Second physical rectifier section; promoted electrical properties populated from identical section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1948 Brimar Radio Valve Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak Inverse Voltage

    2800 V

  • Peak Current per Anode

    650 mA

  • Rectified Current

    250 mA

  • RMS Input per Anode

    1000 V

  • RMS Input per Anode

    750 V

    CapacitorInputFilter

  • Rectified Current

    250 mA

    CapacitorInputFilter

  • Reservoir Capacitor

    4 uF

    CapacitorInputFilter

  • RMS Input per Anode

    850 V

    ChokeInputFilter

  • Rectified Current

    250 mA

    ChokeInputFilter

  • Input Choke Inductance

    5 H

    ChokeInputFilter

Data set 02

1956 RCA Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • HeaterOrFilamentVoltage

    5 V

  • HeaterOrFilamentCurrent

    2 A

Data set 03

1958 Brimar Radio Valve No 7

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • RMS Input per Anode

    750 V

    CapacitorInputFilter

  • Reservoir Capacitance

    4 uF

    CapacitorInputFilter

  • RMS Input per Anode

    1000 V

    ChokeInputFilter

  • Input Choke Inductance

    5 H

    ChokeInputFilter

  • Rectified Current

    250 mA

Data set 04

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Filament/heater voltage

    5 V

    Published condensed-characteristics chart

  • Filament/heater current

    2 A

    Published condensed-characteristics chart

  • DC output current maximum

    250 mA

    FullWave

  • Peak inverse voltage maximum

    2800 V

    FullWave

  • RMS supply voltage per plate maximum

    750 V

    FullWave

  • Peak current per plate maximum

    650 mA

    FullWave

Characteristic

  • Tube voltage drop

    67 V

    At 250 mA DC

Data set 05

195X Raytheon Special Purpose Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak inverse voltage maximum

    2800 V

    FullWave

  • Peak current per plate maximum

    650 mA

    FullWave

  • DC output current maximum

    175 mA

    FullWave

Data set 06

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater voltage

    5 V

  • Heater current

    2 A

Data set 07

1963 Ferranti

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • HeaterOrFilamentVoltage

    5 V

  • HeaterOrFilamentCurrent

    2 A

Other

  • PeakAnodeCurrentPerAnodeMaximum

    650 mA

  • PeakInverseVoltageMaximum

    2100 V

    RectifiedCurrent=250mA

  • PeakInverseVoltageMaximum

    2400 V

    RectifiedCurrent=175mA

  • PeakInverseVoltageMaximum

    2800 V

    RectifiedCurrent=150mA

  • DCOutputCurrentMaximum

    250 mA

    CapacitorInputFilter;PIV=2100V

  • DCOutputCurrentMaximum

    175 mA

    CapacitorInputFilter;PIV=2400V

  • DCOutputCurrentMaximum

    150 mA

    CapacitorInputFilter;PIV=2800V

  • DCOutputCurrentMaximum

    250 mA

    ChokeInputFilter;PIV=2100V

  • DCOutputCurrentMaximum

    250 mA

    ChokeInputFilter;PIV=2400V

  • DCOutputCurrentMaximum

    175 mA

    ChokeInputFilter;PIV=2800V

  • MinimumChokeInductance

    5 H

    PIV=2100V

  • MinimumChokeInductance

    5 H

    PIV=2400V

  • MinimumChokeInductance

    10 H

    PIV=2800V

  • RMSInputVoltagePerAnode

    750 V

    CapacitorInputFilter

  • RMSInputVoltagePerAnode

    850 V

    CapacitorInputFilter

  • RMSInputVoltagePerAnode

    1000 V

    CapacitorInputFilter

  • SupplyImpedanceMinimum

    250 ohm

    CapacitorInputFilter;RMSInput=750V

  • SupplyImpedanceMinimum

    500 ohm

    CapacitorInputFilter;RMSInput=850V

  • SupplyImpedanceMinimum

    575 ohm

    CapacitorInputFilter;RMSInput=1000V

  • Reservoir Capacitance

    4 uF

    CapacitorInputFilter

  • RMSInputVoltagePerAnode

    850 V

    ChokeInputFilter

  • RMSInputVoltagePerAnode

    1000 V

    ChokeInputFilter

  • DC Output Current

    250 mA

    ChokeInputFilter;RMSInput=850V

  • DC Output Current

    175 mA

    ChokeInputFilter;RMSInput=1000V

Data set 08

1966 Tung Sol Electronic Tubes 1 of 4

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum peak inverse voltage

    2800 V

  • Maximum DC output current

    250 mA

    FullWave

  • Maximum steady-state peak plate current per plate

    650 mA

    EachPlate

  • AC plate voltage per plate

    700 V RMS

    CapacitorInputFilter; 2100V PIV rating condition

  • DC output current

    250 mA

    CapacitorInputFilter; 2100V PIV rating condition

  • Effective plate supply resistance per plate

    125 ohm

    CapacitorInputFilter; 2100V PIV rating condition

  • Filter input capacitance

    4 uF

    CapacitorInputFilter; 2100V PIV rating condition

  • DC output voltage

    700 V

    CapacitorInputFilter; 2100V PIV rating condition

  • AC plate voltage per plate

    750 V RMS

    ChokeInputFilter; 2400V PIV rating condition

  • DC output current

    250 mA

    ChokeInputFilter; 2400V PIV rating condition

  • Filter input choke

    5 H

    ChokeInputFilter; 2400V PIV rating condition

  • DC output voltage

    550 V

    ChokeInputFilter; 2400V PIV rating condition

  • AC plate voltage per plate

    950 V RMS

    ChokeInputFilter; 2800V PIV rating condition

  • DC output current

    175 mA

    ChokeInputFilter; 2800V PIV rating condition

  • Filter input choke

    10 H

    ChokeInputFilter; 2800V PIV rating condition

  • DC output voltage

    750 V

    ChokeInputFilter; 2800V PIV rating condition