Data set 01
1962 Eimac
Published operating points and test conditions from this source.
Pentode
Capacitance
Input - - = - - - - - 125 145 pF
145 pF
Output - - - - - - - - 18 24 pF
24 pF
Feedback - - - - - - - .60 pF
60 pF
Input R 55 67 pF
67 pF
Output - - - - - - - - 18 24 pF
24 pF
Other
Maximum plate voltage
7000 V
Maximum screen voltage
1000 V
Maximum plate dissipation
4000 W
Maximum screen dissipation
175 W
Maximum grid dissipation
50 W