Skip to main content

Power - Pentode (NOT beam) (over 1000V 100W) ·Pentode

5C-450A

Standard Valves 5C/450A directly heated thoriated-tungsten RF transmitting pentode for high-power Class C amplification and suppressor-grid modulation, rated 3000 V anode and 450 W dissipation.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 12.5 A

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
12.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Pentode

X-ray radiationInterelectrode capacitances
Transconductance
0.0045 S
Max plate voltage
3000 V
Max screen voltage
850 V
Max plate dissipation
450 W
Max screen dissipation
100 W

Standard Valves 5C/450A RF suppressor-modulated pentode, July 1947 ratings. Max anode 3000 V DC, 0.7 A, 450 W dissipation; screen max 850 V, 100 W dissipation; full ratings to 10 MHz, max anode 2250 V at 20 MHz. Transconductance 0.0045 A/V under manufacturer stated conditions; Cga 0.2 pF, input 45 pF, output 27 pF. Earlier 1940 data gm 0.0065 A/V, input 26 pF, output 39 pF and screen max 650 V; preserve source-specific values. Typical Class C suppressor modulated: Va 2500 V, Ia 300 mA, Vg2 530 V, Vg3 -90 V, Vg1 -165 V, output ~300 W carrier. Unmodulated Class C: Va 2500 V, Ia 590 mA, Vg2 600 V, Ig2 80 mA, Vg3 +100 V, Vg1 -165 V, output ~1 kW. Thoriated tungsten directly heated 10 V 12.5 A filament; free air cooling essential.