Skip to main content

Power - Triode (over 1000V 100W) ·Triode

5924A

Forced-air-cooled power triode designed for FM and television transmitter service, with published Class B television operating data. Its 6 kW plate-dissipation rating supports substantial broadcast-frequency RF power.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
12.6 V / 33 A

Description

5924A is a Triode device. Forced-air-cooled triode for FM and television transmitters; Class-B television sync-level data are published.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
12.6 V
Nominal heater current
33 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
32
Max plate voltage
6000 V
Max plate dissipation
6000 W
Max cathode current
325 mA

Published ratings and characteristics mapped semantically from the source.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1953 Amperex

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    32

    Published source value

Construction

  • Cooling method

    forced air

    Published source value

Data set 02

1958 Amperex Industrial

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    32

  • Maximum frequency full input

    75 MHz

  • Maximum frequency derated

    220 MHz

  • Grid-to-plate capacitance

    11 pF

  • Grid-to-filament capacitance

    16 pF

  • Plate-to-filament capacitance

    0.3 pF

Other

  • Maximum plate dissipation

    6000 W

  • Plate voltage

    5000 V

    ClassB TVService SyncLevel

  • Plate current

    1.9 A

    ClassB TVService SyncLevel

  • Power output

    6250 W

    ClassB TVService SyncLevel

  • Grid voltage

    -140 V

    ClassB TVService SyncLevel

  • Grid current

    350 mA

    ClassB TVService SyncLevel

Data set 03

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate voltage

    5000 V

    ClassB; TVService; SyncLevel

  • Plate current

    1.9 A

    ClassB; TVService; SyncLevel

  • RF output power

    6250 W

    ClassB; TVService; SyncLevel

  • Grid voltage

    -140 V

    ClassB; TVService; SyncLevel

  • Grid current

    350 mA

    ClassB; TVService; SyncLevel

  • Maximum frequency at full input rating

    220 MHz

Capacitance

  • Grid-to-plate capacitance

    11 pF

  • Grid-to-filament capacitance

    16 pF

  • Plate-to-filament capacitance

    0.3 pF