Data set 01
1953 Amperex
Published operating points and test conditions from this source.
Triode
Characteristic
Amplification factor
32
Published source value
Construction
Cooling method
water
Published source value
Power - Triode (over 1000V 100W) ·Triode
Water-cooled low-drive transmitting triode designed for industrial RF-heating applications. Rated for 6 kW plate dissipation and 6 kV plate voltage, with published Class C operation producing approximately 6.9 kW RF output.
5923 is a Triode device. Water-cooled low-drive HF triode for RF heating applications.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics mapped semantically from the source.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Amplification factor
32
Published source value
Cooling method
water
Published source value
Data set 02
Published operating points and test conditions from this source.
Amplification factor
32
Maximum frequency
75 MHz
Grid-to-plate capacitance
110 pF
Grid-to-filament capacitance
16 pF
Plate-to-filament capacitance
0.3 pF
Maximum plate dissipation
6000 W
Plate voltage
6000 V
ClassC
Plate current
1.5 A
ClassC
Power output
6900 W
ClassC
Grid voltage
-400 V
ClassC
Grid current
310 mA
ClassC
Data set 03
Published operating points and test conditions from this source.
Plate current
1.5 A
RFPower
RF output power
6900 W
RFPower
Grid voltage
-400 V
RFPower
Grid current
310 mA
RFPower
Grid-to-plate capacitance
11 pF
Grid-to-filament capacitance
16 pF
Plate-to-filament capacitance
0.3 pF