Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Pentode
Characteristic
Grid No. 1 transconductance
3200 uS
Published datasheet value
Grid No. 3 transconductance
500 uS
Published datasheet value
Voltage Radio Detector Converter ·Pentode
Dual-control sharp-cutoff pentode for gated-amplifier and mixer service to approximately 400 MHz. Separate control grids provide switching and frequency-conversion functions, while its heater rating suits specialized aircraft and military electrical systems.
Sharp-cutoff dual-control pentode intended for gated-amplifier or mixer service at frequencies up to 400 megacycles.
Subminiature 8-lead
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1G1 | A | G1 — Control Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN2K | A | K — Cathode EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN3H | — | H — Heater EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN4G3 | A | G3 — Suppressor Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN5P | A | P — Plate (Anode) EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN6H | — | H — Heater EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN7G2 | A | G2 — Screen Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
| PIN8K | A | K — Cathode EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DC |
1 physical section, each with unique specifications.
Section 1
Dual-control pentode; promoted values use the grid-3-tied-to-cathode condition; second condition retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Grid No. 1 transconductance
3200 uS
Published datasheet value
Grid No. 3 transconductance
500 uS
Published datasheet value
Data set 02
Published operating points and test conditions from this source.
Plate Voltage
100 V
ClassA;Grid3TiedToCathode
Screen Voltage
100 V
ClassA;Grid3TiedToCathode
Cathode Resistor
150 ohm
ClassA;Grid3TiedToCathode
Plate Current
5.6 mA
ClassA;Grid3TiedToCathode
Screen Current
4 mA
ClassA;Grid3TiedToCathode
Plate Resistance
110000 ohm
ClassA;Grid3TiedToCathode
Transconductance
3200 uS
ClassA;Grid3TiedToCathode
Plate Voltage
100 V
ClassA;Grid3Minus1V
Screen Voltage
100 V
ClassA;Grid3Minus1V
Grid3 Voltage
-1 V
ClassA;Grid3Minus1V
Cathode Resistor
150 ohm
ClassA;Grid3Minus1V
Plate Current
4 mA
ClassA;Grid3Minus1V
Screen Current
5.8 mA
ClassA;Grid3Minus1V
Plate Resistance
50000 ohm
ClassA;Grid3Minus1V
Transconductance
1950 uS
ClassA;Grid3Minus1V