Voltage
6.3 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Current
300 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Electrodes and Heater
5.4
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Electrodes and Heater
6.9
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Electrodes and Heater
7.6
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Voltage — published value 1
67.5 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Voltage — published value 2
67.5 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grids-No.2 and No.4 Voltage — published value 1
67.5 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grids-No.2 and No.4 Voltage — published value 2
67.5 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid-No.3 Voltage — published value 1
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid-No.3 Voltage — published value 2
-4 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid-No.l Voltage — published value 1
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid-No.l Voltage — published value 2
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Transconductance
2000
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Transconductance
1100
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 1 —Grid No.l — published value 1
1
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 1 —Grid No.l — published value 2
5
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 2 -Cathode, — published value 1
2
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 2 -Cathode, — published value 2
6
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 3 —Heater — published value 1
3
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 3 —Heater — published value 2
7
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Pin 4 -Heater
4
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
GRID—No."1 SUPPLY VOLTAGE
1 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
DC CATHODE CURRENT
20 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 1
150 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 2
150 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 3
150 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 1
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 2
10 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 3
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Supply Voltage — published value 1
75 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Supply Voltage — published value 2
75 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Supply Voltage — published value 3
75 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 1
10 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 2
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage — published value 3
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Resistance — published value 1
20000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Resistance — published value 2
20000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Resistance — published value 3
20000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Resistance — published value 1
47000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Resistance — published value 2
47000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Resistance — published value 3
47000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current — published value 1
0 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current — published value 2
0 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current — published value 3
5.8 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grids—No.2 6 Na.4
6
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Current — published value 1
0 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Current — published value 2
14 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Current — published value 3
9 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current
0.2 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current — published value 1
2 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current — published value 2
5 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current — published value 3
6.5 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Note Ia
6.3 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
on neater, plate—supply volts = 150, grid-No.3 supply volts =
150 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
0, grids—No.2 6 No.4 sup Ply volts = 75, grl d—No.1 suDPly.volts — published value 1
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
0, grids—No.2 6 No.4 sup Ply volts = 75, grl d—No.1 suDPly.volts — published value 2
6 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
0, grids—No.2 6 No.4 sup Ply volts = 75, grl d—No.1 suDPly.volts — published value 3
75 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
— —10, plate—Circuit resistance (ohms) = 20000, grid—No.3 cl rcuit — published value 1
10 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
— —10, plate—Circuit resistance (ohms) = 20000, grid—No.3 cl rcuit — published value 2
20000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
r e515t once (Ohm S) = 47000, grid 5—N0.2 8 No.4 series rest 5tOr — published value 1
47000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
r e515t once (Ohm S) = 47000, grid 5—N0.2 8 No.4 series rest 5tOr — published value 2
5 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
r e515t once (Ohm S) = 47000, grid 5—N0.2 8 No.4 series rest 5tOr — published value 3
8 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
r e515t once (Ohm S) = 47000, grid 5—N0.2 8 No.4 series rest 5tOr — published value 4
5 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
(ohms) = 470, and grid xo. 1—circuit resistance (ohms) = 47000 — published value 1
470 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
(ohms) = 470, and grid xo. 1—circuit resistance (ohms) = 47000 — published value 2
1 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
(ohms) = 470, and grid xo. 1—circuit resistance (ohms) = 47000 — published value 3
47000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
same as /or Mate la exc epi Lhat grid—No.3 Supply vo1L5 = —10
10 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.