Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Diode
Other
Steady state peak plate current
60 mA
Each plate
Transient peak plate current
350 mA
Each plate
Diode (NOT rectifier) ·Diode-Diode
Subminiature twin diode with separate cathodes for detector, AGC, and low-current rectifier service in industrial and communications equipment.
Subminiature twin diode with separate cathodes for independent operation, suitable for detector, automatic-gain-control and low-current power-rectifier service.
Subminiature 8-lead base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN12P | B | P — Plate (Anode) Original EIA label 2P; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
| PIN22K | B | K — Cathode Original EIA label 2K; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
| PIN3H | — | H — Heater Original EIA label H; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
| PIN4SH | A | SH — Internal Shield Original EIA label SH; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
| PIN51P | A | P — Plate (Anode) Original EIA label 1P; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
| PIN6H | — | H — Heater Original EIA label H; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
| PIN71K | A | K — Cathode Original EIA label 1K; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8DJ |
2 physical sections, each with unique specifications.
Section 1
Representative section for two electrically identical sections.
Section 2
No fixed ratings are recorded for this section.
Second physical diode section added in approved section-structure reconciliation.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Steady state peak plate current
60 mA
Each plate
Transient peak plate current
350 mA
Each plate
Data set 02
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
300 mA
Approximate Detection Frequency
450 MHz
Minimum Diode Resonant Frequency
900 MHz
Each section
Data set 03
Published operating points and test conditions from this source.
Tube voltage drop
4.5 V
At18mADC
DC output current maximum per plate
10 mA
FullWave;EachSection
Peak inverse voltage maximum
460 V
FullWave;EachSection
RMS supply voltage per plate
150 V
FullWave;EachSection
Peak current per plate maximum
60 mA
FullWave;EachSection
Data set 04
Published operating points and test conditions from this source.
AC Plate Supply Voltage Per Plate
165 V
TransientPeakPlateCurrentPerPlate
350 mA
Duration<=0.2s
DC Output Current
18 mA
FullWave;CapacitorInputFilter
Data set 05
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
300 mA
Maximum AC plate-supply voltage per plate RMS
165 V
Full-wave DC output current
18 mA
CapacitorInputFilter
Filter input capacitance
8 uF
CapacitorInputFilter
Maximum peak inverse voltage
460 V
Nominal DC output current
18 mA
Maximum peak forward current
60 mA
Maximum heater-cathode voltage
360 V
Plate1 input capacitance
2.5 pF
Section1
Cathode1 input capacitance
3.5 pF
Section1