Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Pentode
Capacitance
Grid1 To All
2.2 pF
Voltage Pentode ·Pentode
Filamentary electrometer pentode designed for extremely low-current circuitry. It may also be connected as a triode for specialized electrometer applications, making ultra-high-impedance measurement rather than ordinary RF or audio amplification its defining function.
Filamentary electrometer pentode designed for extremely low-current circuitry; it may also be triode-connected for specialized electrometer applications.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted from approved datasheet.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Grid1 To All
2.2 pF
Data set 02
Published operating points and test conditions from this source.
Heater voltage
1.25 V
Heater current
10 mA
Pentode plate voltage
8.5 V
PentodeConnection
Pentode screen voltage
4.5 V
PentodeConnection
Pentode grid 1 voltage
-2 V
PentodeConnection
Pentode plate current
6 uA
PentodeConnection
Pentode screen current
3.6 uA
PentodeConnection
Triode-connected plate voltage
10.5 V
TriodeConnection
Triode-connected grid voltage
-3 V
TriodeConnection
Triode-connected plate current
200 uA
TriodeConnection
Maximum plate voltage
22.5 V
Maximum screen voltage
22.5 V
Maximum cathode current
0.3 mA
Triode-connected transconductance
175 uS
TriodeConnection
Triode-connected amplification factor
1.8
TriodeConnection
Grid1-to-all capacitance
2.2 pF
Grid1-to-grid2-and-plate capacitance
2 pF