Data set 01
1957 Philips Receiving and Amplifying Tubes
Published operating points and test conditions from this source.
CameraPickup
Characteristics
Photocathode Image Width
12 mm
Photocathode Image Height
16 mm
Electron-Optical Image Width
4 mm
Specialized - Photo Tube ·CameraPickup
Image-iconoscope television camera tube using magnetic focusing and deflection for optical image pickup.
The Philips 5854 is an image iconoscope television camera tube with magnetic focusing and deflection.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Image iconoscope television camera tube with magnetic focusing and deflection.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Photocathode Image Width
12 mm
Photocathode Image Height
16 mm
Electron-Optical Image Width
4 mm
Data set 02
Published operating points and test conditions from this source.
Plate voltage
45 V
ClassA
Screen voltage
45 V
ClassA
Control-grid voltage
-2 V
ClassA
Plate current
0.8 mA
ClassA
Screen current
0.25 mA
ClassA
Load resistance
50000 Ω
ClassA
Power output
0.0095 W
ClassA
Plate resistance
350000 Ω
ClassA
Transconductance
550 µS
ClassA
Data set 03
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
630 mA
Focusing and deflection method
Magnetic
Grid-2/collector/signal-electrode voltage
930 V
Maximum grid-1 bias magnitude
- to 100 V
Maximum grid-2/collector/signal-electrode voltage
- to 1110 V
Grid capacitance
- to 8 pF
Maximum
Cathode capacitance
- to 10 pF
Maximum
Signal-electrode capacitance
- to 5 pF
Maximum
Data set 04
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
630 mA
Focusing method
Magnetic
Deflection method
Magnetic
Grid capacitance maximum
8 pF
Signal-electrode capacitance maximum
10 pF
Plate-grid capacitance maximum
5 pF
Operating electrode voltage
930 V
Maximum scanning-electrode voltage
1110 V
Maximum photocathode illumination
400 lux