Data set 01
1940 RCA
Published operating points and test conditions from this source.
Thyratron
Application
Application
RelayControl text
Specialized - Switching Tube ·Thyratron
Industrial cold-cathode glow-discharge triode for relay-control service in low-current on/off circuits. It provides heaterless electronic switching.
Industrial cold-cathode glow-discharge triode for relay-control service in low-current on/off circuits. Extracted from the supplied RCA Receiving Tube Manual excerpt.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1P | A | P — Plate (Anode) EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
| PIN2IC | — | IC EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
| PIN3K | A | K — Cathode EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
| PIN4G1 | A | G1 — Control Grid EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
| PIN5IC | — | IC EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
| PIN6IC | — | IC EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
| PIN7K | A | K — Cathode EIA chart transcription; independent manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 4CK |
1 physical section, each with unique specifications.
Section 1
Cold-cathode glow-discharge switching triode; trigger/breakdown data in parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
RelayControl text
Data set 02
Published operating points and test conditions from this source.
Maximum Plate Voltage
200 V
Maximum Cathode Current
25 mA
Peak Cathode Current
100 mA
Average Cathode Current
25 mA
Starter Triggering Voltage
50 V
Ionization Time
20 us
Deionization Time
500 us
Anode Breakdown Voltage
290 V
Data set 03
Published operating points and test conditions from this source.
Maximum Anode-Starter Voltage
180 V
Maximum Cathode Current
25 mA
Peak Cathode Current
100 mA
Ambient Temperature Minimum
-60 degC
Ambient Temperature Maximum
75 degC
Data set 04
Published operating points and test conditions from this source.
Anode voltage minimum
140 V DC
ColdCathodeTrigger
Anode voltage maximum
200 V DC
ColdCathodeTrigger
AC anode voltage
117 V AC
ColdCathodeTrigger
Starter-to-cathode breakdown voltage minimum
73 V
ColdCathodeTrigger
Starter-to-cathode breakdown voltage maximum
105 V
ColdCathodeTrigger
Anode-to-cathode breakdown voltage
>200 V
ColdCathodeTrigger
Maximum load current
25 mA
ColdCathodeTrigger
Peak load current
100 mA
ColdCathodeTrigger
Data set 05
Published operating points and test conditions from this source.
Anode ignition voltage at starter 0 V
290 V
Starter ignition voltage variable
73 to 105 V
Starter ignition voltage at anode 0 V
80 V
Anode burning voltage at 50 mA
85 V
Anode maintaining voltage at 25 mA
62 V
Starter maintaining voltage at 10 mA
75 V
Starter maintaining voltage at anode current 25 mA
61 V
Anode-starter breakdown voltage
200 to - V
Minimum
Starter transfer current
50 to 400 uA
Anode transfer current
- to 160 uA
Maximum
Ionization time
20 us
Deionization time
500 us
Maximum anode-starter voltage
- to 180 V
Maximum average cathode current
- to 25 mA
Maximum peak cathode current
- to 100 mA
Maximum positive starter peak current
- to 100 mA
Relay-service AC supply voltage
117 V RMS
50Hz
Maximum peak inverse voltage as rectifier
- to 200 V
50Hz
Maximum rectifier current
- to 100 mA
50Hz
Data set 06
Published operating points and test conditions from this source.
Cathode type
Cold
Ionization time
20 us
Deionization time
500 us
Anode voltage drop
62 V
Starter-electrode voltage drop
61 V
Anode breakdown voltage
290 V
Starter-electrode breakdown voltage
80 V
Required transfer current
50 uA
At140VPeak
Peak forward anode and starter-electrode voltage
200 V
Peak inverse anode and starter-electrode voltage
200 V
Data set 07
Published operating points and test conditions from this source.
Peak inverse anode/starter voltage
200 V
FirstQuadrant
Peak forward anode/starter voltage
200 V
FirstQuadrant
Peak cathode current
100 mA
FirstQuadrant
Average cathode current
25 mA
FirstQuadrant
Peak starter-electrode current
100 mA
StarterPositive
AC anode supply voltage RMS
117 V
RelayService 60Hz
Maximum pre-firing starter voltage
70 V
RelayService 60Hz
Minimum triggering starter voltage
35 V
RelayService 60Hz
Minimum firing voltage
105 V
RelayService 60Hz
Data set 08
Published operating points and test conditions from this source.
Filling
Gas; cold cathode
Typical anode ignition voltage
290 V
ControlVoltage=0V
Typical starter ignition voltage
80 V
Maximum anode supply voltage
180 V
Maximum cathode current
25 mA
Maximum peak cathode current
100 mA