Skip to main content

Rectifier - Half Wave ·Rectifier

575A

Convection-cooled mercury-vapor half-wave rectifier for high-voltage power conversion. Its heavy filament and low mercury-arc drop provide ampere-class industrial rectification.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
JUMBO4B
Base pins
-
Nominal heater
5 V / 11.5 A

Description

575A is listed in the supplied Amperex material as a convection-cooled mercury-vapor half-wave rectifier. Published ratings and characteristics were captured from the supplied table.

Socket description

Super Jumbo 4-pin bayonet

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
JUMBO4B
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
11.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
15000 V
Rectifier nominal output current
2.5 A
Rectifier peak forward current
1.5 A
Rectifier forward voltage drop
10 V
Rectifier warm-up time
30 s

Peak inverse rating is temperature-dependent; 15 kV is the highest printed maximum in the source table.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 General Electric Transmitting Types

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • HeaterOrFilamentVoltage

    5 V

Data set 02

1953 Amperex

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Filament preheating period

    30 s

    Published source value

  • Maximum average plate current, out-of-phase filament excitation

    2.5 A

    Published source value

  • Maximum peak plate current, out-of-phase filament excitation

    10 A

    Published source value

Data set 03

1956 RCA Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • HeaterOrFilamentVoltage

    5 V

  • HeaterOrFilamentCurrent

    10 A

Data set 04

1958 Amperex Industrial

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filament heating time

    30 s

    HalfWave;MercuryVapor

  • Tube voltage drop

    10 V

    HalfWave;MercuryVapor

Other

  • Peak inverse anode voltage maximum

    15000 V

    HalfWave;MercuryVapor

  • Peak anode current maximum

    6 A

    HalfWave;MercuryVapor

  • Average anode current maximum

    1.5 A

    HalfWave;MercuryVapor

  • Surge current maximum

    60 A

    HalfWave;MercuryVapor

  • Recommended mercury temperature range

    +20 to +50 °C

    MercuryVapor

Data set 05

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Anode starting voltage

    20 V

Other

  • Filament heating time

    30 s

Data set 06

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filament voltage

    5 V

    MercuryVaporRectifier

  • Filament current

    10 A

    MercuryVaporRectifier

  • Heating time

    30 s

    MercuryVaporRectifier

  • Tube voltage drop

    10 V

    MercuryVaporRectifier

Other

  • Maximum peak inverse voltage

    15000 V

    HalfWave MercuryVapor

  • Maximum peak plate current

    6 A

    HalfWave MercuryVapor

  • Maximum DC output current

    1.5 A

    HalfWave MercuryVapor

  • Maximum frequency

    60 Hz

    HalfWave MercuryVapor

Data set 07

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Filament Voltage

    5 V

  • Filament Current

    9.0-11.5 A

  • Filament Heating Time

    30 s

  • Peak Inverse Anode Voltage

    15000 V

  • Peak Anode Current - Quadrature

    10 A

  • Peak Anode Current - In Phase

    6 A

  • Average Anode Current - Quadrature

    2.5 A

  • Average Anode Current - In Phase

    1.5 A

  • Maximum AC Short-Circuit Current

    100 A

  • Condensed Mercury Temperature Range

    20-50 C

Data set 08

1971 Machlette Laboratories

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum frequency

    150 Hz

Data set 09

1971 RCA HB3 Binder 6 of 7

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak Inverse Anode Voltage

    15000 V

    Mercury-vapor half-wave rectifier

  • Peak Anode Current, Quadrature Filament Excitation

    10 A

    Mercury-vapor half-wave rectifier

  • Average Anode Current, Quadrature Filament Excitation

    2.5 A

    Mercury-vapor half-wave rectifier

  • Average Anode Current, In-Phase Filament Excitation

    1.5 A

    Mercury-vapor half-wave rectifier

  • Maximum AC Short-Circuit Current

    100 A

    Mercury-vapor half-wave rectifier

Characteristics

  • Tube Voltage Drop

    10 V

    Mercury-vapor half-wave rectifier

  • Minimum Filament Heating Time

    30 s

    Mercury-vapor half-wave rectifier

Data set 10

1975 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filament Current Range

    9 A to 11.5 A

Other

  • Anode Starting Voltage

    20 V

  • Condensed Mercury Temperature Range 15kV

    20 to 50 C

  • Condensed Mercury Temperature Range 10kV

    20 to 60 C

  • Peak Anode Current Quadrature

    10 A

  • Peak Anode Current InPhase

    7 A

  • Average Anode Current Quadrature

    2.5 A

  • Average Anode Current InPhase

    1.75 A

  • AC Short Circuit Current Maximum

    100 A

Data set 11

1976 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filament Current Range

    9 A to 11.5 A

Other

  • Anode Starting Voltage

    20 V

  • Condensed Mercury Temperature Range 15kV

    20 to 50 C

  • Condensed Mercury Temperature Range 10kV

    20 to 60 C

  • Peak Anode Current Quadrature

    10 A

  • Peak Anode Current InPhase

    7 A

  • Average Anode Current Quadrature

    2.5 A

  • Average Anode Current InPhase

    1.75 A

  • AC Short Circuit Current Maximum

    100 A