Data set 01
1940 RCA
Published operating points and test conditions from this source.
Thyratron
Application
Application
Relay_GridControlledRectifier_PulseModulator text
Specialized - Thyratron ·Thyratron
Gas thyratron tetrode for relay operation, grid-controlled rectification, and pulse switching. Its control grid initiates rapid gas-discharge conduction.
Directly heated gas thyratron tetrode for relay operation, grid-controlled rectification, and pulse switching.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 0
Thyratron section. Forward peak anode voltage and peak cathode current promoted; inverse/pulse ratings preserved as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
Relay_GridControlledRectifier_PulseModulator text
Data set 02
Published operating points and test conditions from this source.
Heater or filament voltage
6.3 V
Section1
Heater or filament current
600 mA
Section1
Peak forward voltage maximum
650 V
Thyratron
Peak inverse voltage maximum
1300 V
Thyratron
Peak anode current maximum
500 mA
Thyratron
Average anode current maximum
100 mA
Thyratron
Maximum grid voltage
-100 V
Thyratron
Filament heating time
10 s
Thyratron
Tube voltage drop
8 V
Thyratron
Ionization time
0.5 µs
Thyratron
Deionization time
35 min
Thyratron
Data set 03
Published operating points and test conditions from this source.
Prototype / equivalent family
2D21
Application
Relay / grid-controlled rectifier / pulse modulator
Peak forward anode voltage
650 V
Pulse
Peak cathode current
500 mA
Pulse
Fault cathode current
10 A
Pulse
Data set 04
Published operating points and test conditions from this source.
Peak Inverse Anode Voltage
1300 V
GridControlledRectifier
Average Cathode Current
100 mA
GridControlledRectifier
Fault Cathode Current
10 A
0.1Second
Pulse Peak Cathode Current
10 A
PulseModulator
Anode Voltage Drop
8 V
Data set 05
Published operating points and test conditions from this source.
HeaterVoltageNominal
6.3 V
Nominal
HeaterCurrentNominal
600 mA
Nominal
Maximum Plate Voltage
650 V
Maximum Cathode Current
100 mA
Peak Cathode Current
500 mA
Relay/controlled-rectifier service
MaximumInverseAnodeVoltage
1300 V
Data set 06
Published operating points and test conditions from this source.
Peak forward anode voltage
650 V
Peak inverse anode voltage
1300 V
Peak cathode/anode current
500 mA
Average cathode/anode current
100 mA
Fault or surge current
10 A
ShortDuration
Peak heater-cathode voltage heater negative
100 V
Peak heater-cathode voltage heater positive
25 V
Ambient temperature range
-75 C minimum
Heater voltage
6.3 V
Heater current
600 mA
Pulse-modulator peak anode voltage
500 V
PulseModulator
Pulse-modulator peak cathode current
10 A
PulseModulator
Pulse-modulator current rate of change
100 A/us
PulseModulator
Ionization time
0.5 us
Approximate
Deionization time
35 us
Approximate
Anode voltage drop
8 V
Conducting
Minimum heating time
20 s
BeforeConduction
Gas fill
Gas
Grid-to-anode capacitance
0.026 pF
Approximate
Grid-to-cathode capacitance
2.4 pF
Approximate
Data set 07
Published operating points and test conditions from this source.
Peak forward anode voltage
500 V
PulseModulator
Peak inverse anode voltage
100 V
PulseModulator
Peak cathode current
10 A
PulseModulator
Average cathode current
10 mA
PulseModulator
Cathode heating time
20 s
Grid No.1 to anode capacitance
0.026 pF
Input capacitance
2.4 pF
Output capacitance
1.6 pF
Ionization time
0.5 us