Data set 01
1940 RCA
Published operating points and test conditions from this source.
Thyratron
Application
Application
Relay_Counter_Control text
Specialized - Thyratron ·Thyratron
Industrial gas-tetrode thyratron for counter and relay applications. Grid-controlled gas discharge provides electronic switching and control.
Industrial gas-tetrode thyratron used in counter-circuit and relay applications. Extracted from the supplied RCA Receiving Tube Manual excerpt.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1G1 | A | G1 — Control Grid EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
| PIN2K | A | K — Cathode EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
| PIN3H | — | H — Heater EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
| PIN4H | — | H — Heater EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
| PIN5G2 | A | G2 — Screen Grid EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
| PIN6P | A | P — Plate (Anode) EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
| PIN7G2 | A | G2 — Screen Grid EIA chart transcription; independent manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BN |
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted where unambiguous; additional source values preserved as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
Relay_Counter_Control text
Data set 02
Published operating points and test conditions from this source.
U_f
6.3 V
U_f 6,3 V 8
Ui
11 V
Ui 11 V
Uz
40 V
Uz 40 V
Cg1/a ca
0.05 pF
Cg1/a ca. 0,05 pF Fassung: 7-10, TGL 11607
J a8 max
500 V
J a8 max. 500 V maX. 10 v
Eks max
100 mA
Eks max. 100 mA maX. 100 kOhm 3)
Di. max
25 mA
Di. max. 25 mA MmaX. 30 5
U g1 max
100 v
U g1 max. 100 v 2)
1 mMaX
100 V
1 mMaX. 100 V
U 18 MaX
10 V
-U 18 MaX. 10 V maX. 25 V
x1 MAaX
5 mA
x1 MAaX. 5 mA MaXe 90 °
R mM8aX
10 MOhm
R mM8aX. 10 MOhm maX. 30 °
PublishedValue
1 v
1 v 1)
Ug
2 S
-Ug2 S MAX . 50
Zündkennlinien-Streubereiche bei 4 =
0.1 MOhm
Zündkennlinien-Streubereiche bei 4 = 0,1 MOhm und Ry4 = 10 MOhm,
oder Überheizung (
6.9 V
oder Überheizung (6,9 V) auftreten können.
Data set 03
Published operating points and test conditions from this source.
Application
Relay control
Data set 04
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Nominal
Heater current
150 mA
Nominal
Maximum cathode current
100 mA
Minimum cathode heating time
10 s
Anode-to-control-grid capacitance
0.03 pF
Data set 05
Published operating points and test conditions from this source.
Warmup time minimum
10 s
Thyratron
Arc voltage drop
10 V
Thyratron
Anode-to-grid-1 striking ratio
250
Thyratron
Anode-to-grid-2 striking ratio
15
Thyratron
Critical grid-1 current
0.5 µA
Thyratron
Deionization time
40 µs
RecoveryTest
Recovery-test anode voltage
500 V
RecoveryTest
Recovery-test peak cathode current
100 mA
RecoveryTest
Pulse duration
20 µs
RecoveryTest
Grid-1 voltage
-50 V
RecoveryTest
Peak forward anode voltage maximum
500 V
Section1
Peak inverse anode voltage maximum
500 V
Section1
Peak cathode current maximum
100 mA
Section1
Surge cathode current maximum
2 A
Section1
Ambient temperature range
-55 to +90 °C
Section1
Data set 06
Published operating points and test conditions from this source.
Peak inverse anode voltage
500 V
Switching
Peak forward anode voltage
500 V
Switching
Peak cathode current
100 mA
Switching
Average cathode current
25 mA
Switching
Surge cathode current
2 A
0.1Second
Anode voltage drop
10 V
Critical grid current
0.5 uA
Ebb=350Vrms
Minimum cathode heating time
10 s
De-ionization time
25 us
Grid=-100V
De-ionization time
40 us
LowNegativeGridVoltage
Ionization time
0.5 us
Anode-to-control-grid capacitance
0.03 pF
Control-grid-to-cathode capacitance
1.8 pF
ShieldGridIncluded
Data set 07
Published operating points and test conditions from this source.
Peak forward anode voltage
500 V
Peak inverse anode voltage
500 V
Peak cathode/anode current
100 mA
Average cathode/anode current
25 mA
Fault or surge current
2 A
ShortDuration
Peak heater-cathode voltage heater negative
100 V
Peak heater-cathode voltage heater positive
25 V
Ambient temperature range
-55 to +90 C
Heater voltage
6.3 V
Heater current
150 mA
Relay-service RMS anode voltage
117 V
RelayService
Ionization time
0.5 us
Approximate
Deionization time
25 us
Approximate
Anode voltage drop
10 V
Conducting
Grid No.2 control ratio
15
Grid No.1 control ratio
250
Gas fill
Gas
Grid-to-anode capacitance
0.03 pF
Approximate
Grid-to-cathode capacitance
1.6 pF
Approximate
Data set 08
Published operating points and test conditions from this source.
Peak forward anode voltage
500 V
RelayService
Peak inverse anode voltage
500 V
RelayService
Peak cathode current
100 mA
RelayService
Average cathode current
25 mA
RelayService
Surge cathode current
2 A
0.1Second
Anode voltage drop
10 V
Ionization time
0.5 us
Grid No.1 to anode capacitance
0.03 pF
Input capacitance
1.8 pF
Output capacitance
0.54 pF
Data set 09
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
150 mA
Anode arc voltage
15 V
Recovery time
40 us
Va=500V;Ikp=100mA
Minimum heater warmup time
10 sec
Filling
Inert gas
Maximum anode voltage
500 V
Maximum surge current
100 mA
Duration<=0.1s