Skip to main content

Voltage - Dual Triode (similar) ·Triode-Triode

5687WA

Ruggedized high-perveance medium-mu twin triode intended for pulse, industrial, military airborne, and standby-trigger applications, with unusually high shock and acceleration ratings.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
B9A
Base pins
9
Nominal heater
12.6 V / 450 mA

Description

Ruggedized high-perveance medium-mu twin triode for pulse, industrial, military airborne, and standby-trigger applications.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
12.6 V
Nominal heater current
450 mA
Parallel heater voltage
6.3 V
Parallel heater current
900 mA
Series capable
Yes

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
2000 Ω
Transconductance
0.0085 S
Amplification factor
17
Max plate voltage
250 V
Max plate dissipation
4.2 W
Max cathode current
50 mA

Representative row for two ruggedized high-perveance triodes.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
2000 Ω
Transconductance
0.0085 S
Amplification factor
17
Max plate voltage
250 V
Max plate dissipation
4.2 W
Max cathode current
50 mA

Second physical triode restored under current one-row-per-physical-section policy.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater voltage

    12.6 V

    Nominal

  • Heater current

    450 mA

    Nominal

Data set 02

1966 Tung Sol Electronic Tubes 3 of 4

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate voltage

    180 V

    ClassA;EachSection

  • Grid voltage

    -7 V

    ClassA;EachSection

  • Plate current

    23 mA

    ClassA;EachSection

  • Maximum inverse plate voltage

    1000 V

    Pulse

  • Total plate dissipation both units

    7.5 W

    BothSections

  • Maximum shock

    450 G

    Ruggedized

  • Maximum uniform acceleration

    1000 G

    Ruggedized

  • Maximum vibrational acceleration

    2.5 G

    Ruggedized

Characteristic

  • Plate resistance

    2000 ohm

    ClassA;EachSection

  • Transconductance

    8500 uS

    ClassA;EachSection

  • Amplification factor

    17

    ClassA;EachSection

Capacitance

  • Grid-to-plate capacitance

    4 pF

    EachSection

  • Heater-to-cathode capacitance

    7 pF

    EachSection

  • Plate-to-plate capacitance

    0.75 pF

    BetweenSections