Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Triode
Other
Heater voltage
12.6 V
Nominal
Heater current
450 mA
Nominal
Voltage - Dual Triode (similar) ·Triode-Triode
Ruggedized high-perveance medium-mu twin triode intended for pulse, industrial, military airborne, and standby-trigger applications, with unusually high shock and acceleration ratings.
Ruggedized high-perveance medium-mu twin triode for pulse, industrial, military airborne, and standby-trigger applications.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Representative row for two ruggedized high-perveance triodes.
Section 2
Second physical triode restored under current one-row-per-physical-section policy.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater voltage
12.6 V
Nominal
Heater current
450 mA
Nominal
Data set 02
Published operating points and test conditions from this source.
Plate voltage
180 V
ClassA;EachSection
Grid voltage
-7 V
ClassA;EachSection
Plate current
23 mA
ClassA;EachSection
Maximum inverse plate voltage
1000 V
Pulse
Total plate dissipation both units
7.5 W
BothSections
Maximum shock
450 G
Ruggedized
Maximum uniform acceleration
1000 G
Ruggedized
Maximum vibrational acceleration
2.5 G
Ruggedized
Plate resistance
2000 ohm
ClassA;EachSection
Transconductance
8500 uS
ClassA;EachSection
Amplification factor
17
ClassA;EachSection
Grid-to-plate capacitance
4 pF
EachSection
Heater-to-cathode capacitance
7 pF
EachSection
Plate-to-plate capacitance
0.75 pF
BetweenSections