Data set 01
1942 Electrons Inc
Published operating points and test conditions from this source.
Thyratron
Characteristics
Heating time
30 s
Published datasheet value
Critical grid current
10 uA
Published datasheet value
Specialized - Thyratron ·Thyratron
Xenon-filled three-electrode thyratron for reliable wide-temperature control service. Grid triggering provides controlled gas conduction across demanding environments.
Xenon-filled three-electrode thyratron for reliable wide-temperature control service.
Medium-shell UX 4-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published rectifier/control ratings promoted where applicable.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heating time
30 s
Published datasheet value
Critical grid current
10 uA
Published datasheet value
Data set 02
Published operating points and test conditions from this source.
Heater or filament voltage
2.5 V
Section1
Heater or filament current
8.5 A
Section1
Peak forward voltage maximum
1000 V
Thyratron
Peak inverse voltage maximum
1250 V
Thyratron
Peak anode current maximum
30 A
Thyratron
Average anode current maximum
2.5 A
Thyratron
Maximum grid voltage
-300 V
Thyratron
Filament heating time
60 s
Thyratron
Tube voltage drop
10 V
Thyratron
Ionization time
10 µs
Thyratron
Deionization time
1000 µs
Thyratron
Data set 03
Published operating points and test conditions from this source.
Filament voltage
2.5 V
Nominal
Filament current
9 A
Nominal
Maximum deionization time
1000 us
Maximum critical grid current
10 uA
Maximum anode voltage drop at end of life
14 V
Maximum commutation factor
0.66 VA/us^2
Peak forward anode voltage
1000 V
Peak inverse anode voltage
1250 V
Peak negative grid voltage before conduction
100 V
Peak anode/cathode current
30 A
Average anode/cathode current
2.5 A
Fault current
300 A
Short-duration fault rating
Ambient or condensed-mercury operating temperature range
-55 to +75 C
Minimum heating time prior to tube conduction
30 s
Anode voltage drop at beginning of life
10 V
Grid control ratio
200
Approximate; stated grid-resistor and DC conditions
Grid-to-anode capacitance
2 pF
Approximate
Grid-to-cathode capacitance
14 pF
Approximate