The 5671 is a high-power cooled triode. The supplied datasheet was processed for heater or filament data, maximum ratings, operating characteristics, capacitances, cooling/service conditions, and power-output data. Condition-specific transmitting ratings are retained in the section-parameter table.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
11 V
Nominal heater current
285 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
40
Max plate voltage
15000 V
Max plate dissipation
25000 W
Max cathode current
50 A

forced-air-cooled power triode

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1971 RCA HB3 Binder 6 of 7

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum DC Plate Voltage

    15000 V

    Forced-air-cooled power triode

  • Plate Dissipation

    25 kW

    Forced-air-cooled power triode

  • Typical DC Plate Voltage

    15000 V

    Forced-air-cooled power triode

  • Maximum-Signal Power Output

    100 kW

    Forced-air-cooled power triode

  • Peak Cathode Current

    50 A

    Forced-air-cooled power triode

Characteristics

  • Amplification Factor

    40

    Forced-air-cooled power triode

  • Grid-to-Plate Capacitance

    50 pF

    Forced-air-cooled power triode

  • Grid-to-Filament Capacitance

    90 pF

    Forced-air-cooled power triode

  • Plate-to-Filament Capacitance

    1.5 pF

    Forced-air-cooled power triode