Data set 01
1958 Amperex Industrial
Published operating points and test conditions from this source.
Magnetron
Characteristic
Frequency minimum
2900 MHz
PulsedMagnetron;MechanicalTuning
Frequency maximum
3100 MHz
PulsedMagnetron;MechanicalTuning
Other
Pulsed power output minimum
800 kW
PulsedMagnetron
Average power output approximately
400 W
PulsedMagnetron
Pulsed plate voltage
30 kV
PulsedMagnetron
Pulsed plate current
70 A
PulsedMagnetron
Average plate current
35 mA
PulsedMagnetron
Magnetic field
2700 G
PulsedMagnetron
Duty factor
0.0005
PulsedMagnetron
Construction
Tuning method
Mechanical
PulsedMagnetron