Skip to main content

Specialized - Thyratron ·Thyratron

5559

Grid-controlled gas thyratron for industrial power switching and controlled rectification. Published ratings support substantial controlled-current service.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B4
Base pins
4
Nominal heater
5 V / 4.7 A

Description

5559 is listed in the supplied Amperex material as a grid-controlled gas thyratron. Published ratings and operating characteristics were captured from the supplied table.

Socket description

European 4-pin base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B4
Base pins
4
Nominal heater voltage
5 V
Nominal heater current
4.7 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
1000 V
Max cathode current
2.5 A

Published maximum ratings and device-specific characteristics are promoted where schema-compatible; remaining switching/gauge/regulator electrical data is retained in section parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1958 Amperex Industrial

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Heater or filament voltage

    5 V

    Section1

  • Heater or filament current

    4.5 A

    Section1

  • Peak forward voltage maximum

    1000 V

    Thyratron

  • Peak inverse voltage maximum

    1500 V

    Thyratron

  • Peak anode current maximum

    15 A

    Thyratron

  • Average anode current maximum

    2.5 A

    Thyratron

  • Maximum grid voltage

    -500 V

    Thyratron

Characteristic

  • Filament heating time

    300 s

    Thyratron

  • Tube voltage drop

    16 V

    Thyratron

  • Ionization time

    10 µs

    Thyratron

  • Deionization time

    1000 µs

    Thyratron

Data set 02

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Filament voltage

    5 V

    ThyratronService

  • Filament current

    4.5 A

    ThyratronService

  • Filament heating time

    300 s

    ThyratronService

  • Tube voltage drop

    16 V

    ThyratronService

  • Deionization time

    10 us

    ThyratronService

Other

  • Maximum peak forward voltage

    1000 V

    ThyratronService

  • Maximum peak inverse voltage

    1500 V

    ThyratronService

  • Maximum peak anode current

    15 A

    ThyratronService

  • Maximum average anode current

    2.8 A

    ThyratronService

  • Maximum grid voltage

    -500 V

    ThyratronService

Data set 03

1971 English Electric Valve

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak forward anode voltage

    1 kV

  • Peak inverse anode voltage

    1.5 kV

  • Peak anode current

    15 A

  • Mean anode current

    2.5 A

  • Cathode preheating time

    5 min

Data set 04

1971 RCA HB3 Binder 2 of 7

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristics

  • Voltage

    5 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Current

    4.5 A

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Ionization Time (Approx.)

    10 s

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Deionization Time (Approx.) 1000

    1000 s

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Anode Voltage Drop (Approx.) 16

    16 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • resistor finegotmsl -0 — published value 1

    0

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • resistor finegotmsl -0 — published value 2

    220

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • COND.~AERCURY TEMPERATURE RANGE'

    40 C

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • TEMPERATURE SHOU1..0

    0

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • COND-MERCVRY TEMPERATURE=40~C

    40

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • GRID RESISTOR OHMS)=0

    0 ohm

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • TYPE 5559

    5559 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • CONDENSED-MERCURY TEMPERATURE=40•C

    40

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • GRID RESISTOR (OHMS)=0

    0 ohm

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Heater or filament voltage nominal

    5 V

    Nominal value from supplied datasheet.

  • Heater or filament current nominal

    4.5 A

    Nominal or average value from supplied datasheet.

Other

  • Forward

    1000 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Inverse

    1000 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Before Conduction

    -500 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • During Conduction

    -10 V

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Average`"

    2.5 mA

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Fault, for 0.1 sec. maximum — published value 1

    0.1 mA

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • Fault, for 0.1 sec. maximum — published value 2

    200 mA

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.

  • OPERATING FREQUENCY

    150 mA

    Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.