Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

50Y6GTG

Twin-diode high-vacuum rectifier with two separate sections for AC/DC receiver power supplies. Its 50 V heater supports voltage-doubler, full-wave, or half-wave operation.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
IO
Base pins
7
Nominal heater
50 V / 150 mA

Description

The 50Y6GT/G contains two separate rectifier sections for voltage-doubler, full-wave, or half-wave power-supply service in AC/DC receivers.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
IO
Base pins
7
Nominal heater voltage
50 V
Nominal heater current
150 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
700 V
Rectifier nominal output current
75 mA
Rectifier peak forward current
450 mA
Rectifier forward voltage drop
22 V
Rectifier max heater-cathode voltage
350 V

Two electrically equivalent rectifier sections; identical-section compression applied.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
700 V
Rectifier nominal output current
75 mA
Rectifier peak forward current
450 mA
Rectifier forward voltage drop
22 V
Rectifier max heater-cathode voltage
350 V

Second physical rectifier section; electrical properties populated from applicable published ratings.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1966 Tung Sol Electronic Tubes 3 of 4

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum AC plate voltage RMS

    235 V

  • Maximum peak inverse voltage

    700 V

  • Maximum steady-state peak plate current per plate

    450 mA

    EachSection

  • Voltage-doubler AC voltage per plate

    117 V

    VoltageDoubler

  • Voltage-doubler DC output current

    75 mA

    VoltageDoubler

  • Half-wave DC output current per plate

    75 mA

    HalfWaveRectifier

  • Rectifier maximum peak inverse voltage

    700 V

    PromotedValue

  • Rectifier nominal output current

    75 mA

    PromotedValue

  • Rectifier peak forward current

    450 mA

    PromotedValue

  • Rectifier maximum heater-cathode voltage

    350 V

    PromotedValue

Characteristics

  • Tube voltage drop at 150 mA per plate

    22 V

    EachSection

  • Rectifier forward voltage drop

    22 V

    PromotedValue

SECTION 2

Rectifier

Other

  • Maximum AC plate voltage RMS

    235 V

  • Maximum AC plate voltage RMS

    235 V

  • Maximum peak inverse voltage

    700 V

  • Maximum peak inverse voltage

    700 V

  • Maximum steady-state peak plate current per plate

    450 mA

    EachSection

  • Maximum steady-state peak plate current per plate

    450 mA

    EachSection

  • Voltage-doubler AC voltage per plate

    117 V

    VoltageDoubler

  • Voltage-doubler AC voltage per plate

    117 V

    VoltageDoubler

  • Voltage-doubler DC output current

    75 mA

    VoltageDoubler

  • Voltage-doubler DC output current

    75 mA

    VoltageDoubler

  • Half-wave DC output current per plate

    75 mA

    HalfWaveRectifier

  • Rectifier maximum peak inverse voltage

    700 V

    PromotedValue

  • Rectifier nominal output current

    75 mA

    PromotedValue

  • Rectifier peak forward current

    450 mA

    PromotedValue

  • Rectifier maximum heater-cathode voltage

    350 V

    PromotedValue

Characteristics

  • Tube voltage drop at 150 mA per plate

    22 V

    EachSection

  • Tube voltage drop at 150 mA per plate

    22 V

    EachSection

  • Rectifier forward voltage drop

    22 V

    PromotedValue