Skip to main content

Specialized - Photo Tube ·PhotoemissiveDetector

50AVP

Eleven-stage Amperex photomultiplier with at least 32 mm useful photocathode diameter. Cascaded secondary-emission stages provide high internal gain for sensitive measurement of very low optical signal levels.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
Duodecal
Socket code
B12C
Base pins
12
Nominal heater
-

Description

50AVP is a PhotoTube device in the supplied Amperex literature. Eleven-stage Amperex photomultiplier tube with 32 mm minimum useful photocathode diameter.

Socket description

Duodecar 12-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
Duodecal
Socket code
B12C
Base pins
12
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Duodecal - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

PhotoemissiveDetector

X-ray radiationInterelectrode capacitances
Max plate voltage
2250 V
Max plate dissipation
0.5 W

Photomultiplier structure with photocathode and dynode chain.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

PhotoemissiveDetector

Characteristics

  • Anode-to-last-dynode Capacitance

    3 pF

  • Anode Capacitance

    5 pF

Data set 02

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

PhotoemissiveDetector

Other

  • Minimum useful photocathode diameter

    32 mm

  • Number of stages

    11 count

  • Base

    duodecal

  • Recommended supply voltage

    1800 V

  • Minimum photocathode-to-first-dynode voltage

    180 V

  • Minimum voltage between other electrodes

    80 V

  • Minimum D1-to-D2 voltage

    160 V

    50AVP special instruction

Characteristic

  • Maximum spectral response wavelength

    4200 angstrom

  • Minimum photocathode sensitivity

    25 uA/lm

  • Average photocathode sensitivity

    50 uA/lm

  • Minimum anode sensitivity

    60 A/lm

Data set 03

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

PhotoemissiveDetector

Characteristic

  • Number of stages

    11

  • Photocathode useful diameter

    min 32 mm

  • Wavelength maximum response

    4200 ±300 angstrom

  • Luminous sensitivity

    50 uA/lm

  • Current amplification

    60 to - A/lm

    Vb=1800V; Vs=147V

  • Anode dark current

    max 50e-9 A

Capacitance

  • Anode capacitance

    5 pF

  • Anode-to-last-dynode capacitance

    3 pF

Other

  • Anode current max

    0.7 mA