Skip to main content

Specialized - Thyratron ·Thyratron

502A

Gas-filled negative-control triode thyratron designed for high-sensitivity relay-control service, providing grid-triggered switching from comparatively small control signals.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
6BS
Socket code
B7G
Base pins
6
Nominal heater
6.3 V / 600 mA

Description

Gas-filled negative-control triode thyratron for high-sensitivity relay-control service.

Socket description

Miniature 7-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
6BS
Socket code
B7G
Base pins
6
Nominal heater voltage
6.3 V
Nominal heater current
600 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

6BS - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN1ISAIS — Internal Screen

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

PIN2H—H — Heater

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

PIN3PAP — Plate (Anode)

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

PIN5G1AG1 — Control Grid

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

PIN6G2AG2 — Screen Grid

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

PIN7H—H — Heater

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

PIN8KAK — Cathode

Chart transcription; manufacturer cross-check pending

Unverified

EIA Base Connections, printed page 127, 6BS

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max cathode current
100 mA

Published maximum ratings, operating characteristics, rectifier/deflection data reviewed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Heater/filament voltage

    6.3 V

    Published heater/filament rating

  • Heater/filament current

    600 mA

    Published heater/filament rating

  • Anode voltage drop

    8 V

    ControlledRectifier

Other

  • Maximum DC cathode current

    100 mA

    ControlledRectifier

  • Maximum peak inverse voltage

    1300 V

    ControlledRectifier

  • Maximum peak cathode current

    1 A

    ControlledRectifier

Data set 02

1960 RCA Industrial and Communications Types

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Application

  • Application

    High-sensitivity relay control

Other

  • Peak forward anode voltage

    650 V

    Pulse

  • Peak inverse anode voltage

    1300 V

    Pulse