Data set 01
1958 Amperex Industrial
Published operating points and test conditions from this source.
Magnetron
Other
Frequency
2785 to 2820 MHz
Pulsed RF output power
700 kW
Pulsed
Average RF output power
350 W
Pulsed
Pulsed plate voltage
25 kV
Pulsed
Pulsed plate current
60 A
Pulsed
Average plate current
30 mA
Pulsed
Magnetic field
2700 Gauss
Duty factor
0.0005
Pulsed