Skip to main content

Power - Beam (NOT sweep) (over 1000V 100W) ·BeamPower

4CX600A

Compact radial-beam tetrode designed for distributed amplifiers and UHF service to approximately 1.3 GHz, with low inductance, low capacitance, and 600 W plate dissipation.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6 V / 4.8 A

Description

The 4CX600A is a compact radial-beam tetrode with low lead inductances and low inter- electrode capacitances, designed for use in distributed amplifiers and in UHF service up to 1300 Mc. Maximum plate dissipation is 600 watts. A feature of this tube is the integral screen-cathode by-pass capacitor. One side of the heater is terminated in a ‘‘deck’’ attached to this capacitor while the other heater contact is brought out on a pin on the tube base. The control grid is brought out to four threaded pins on the base.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6 V
Nominal heater current
4.8 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Beam Power

X-ray radiationInterelectrode capacitances
Transconductance
0.025 S
Amplification factor
8
Max plate voltage
3000 V
Max screen voltage
400 V
Max plate dissipation
600 W
Max screen dissipation
15 W
Max grid dissipation
3 W
Max cathode current
500 mA

Single electrical section; values mapped from printed ratings/characteristics.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Other

  • The

    0 a

    The 4CX600A is a compact radial-beam tetrode with low lead inductances and low inter-

  • to

    600 watts

    to 1300 Mc. Maximum plate dissipation is 600 watts.

  • Heater Voltage - - - - - - -~

    6 Volts

    Heater Voltage - - - - - - -~ - 6.0 Volts

  • Current (average)

    4.8 Amperes

    Current (average) - - - - - - 4.8 Amperes

  • Transconductance (I=

    25000 mA

    Transconductance (I= 300 mA) - - - ~ - 25,000 umhos

  • Input - - - - ~

    42 uuf

    Input - - - - ~ - - - 42 uuf

  • Output -~ - - - - - ~

    10 uuf

    Output -~ - - - - - ~ - 10 uuf

  • Screen-cathode

    110 uuf

    Screen-cathode - - - - - - - 110 uuf

  • DC Plate Voltage

    3000 Volts

    DC Plate Voltage- - 3000 Max. Volts

  • DC Screen Voltage

    400 Volts

    DC Screen Voltage 400 Max. Volts

  • DC Grid Voltage - - - - - = - - =

    150 Volts

    DC Grid Voltage - - - - - = - - =150 Max. Volts

  • DC Plate Current

    500 mA

    DC Plate Current - - - - - - - 500 Max. mA

  • Plate Dissipation- - - - ~

    600 Watts

    Plate Dissipation- - - - ~ - - - 600 Max., Watts

  • Screen Dissipation

    15 Watts

    Screen Dissipation - - - - - - - 15 Max. Watts

  • Grid Dissipation =

    3 Watts

    Grid Dissipation = - - - - - - - 3 Max. Watts

  • (Bffactive

    1963 A

    (Bffactive 5=7-63) © Copyright 1963 by Eltel=MeCullough, Inc. Printed In U.S.A,

Data set 02

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Characteristic

  • Heater/Filament Voltage

    6 V

  • Heater/Filament Current

    4.8 A

  • Amplification Factor

    8

  • Transconductance

    25000 uS

Other

  • Maximum DC Plate Voltage

    3000 V

  • Maximum DC Screen Voltage

    400 V

  • Maximum Plate/Cathode Current

    500 mA

  • Maximum Plate Dissipation

    600 W

  • Maximum Screen Dissipation

    15 W

  • Maximum Grid Dissipation

    3 W

  • Frequency for Maximum Ratings

    1300 MHz

Construction

  • Cooling

    Forced air