Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Thyratron
Characteristics
Gas filling
Hydrogen
Other
Starting anode voltage minimum
2500 V
Peak inverse anode voltage maximum
8000 V
Specialized - Thyratron ·Thyratron
Hot-cathode grid-controlled hydrogen thyratron for high-voltage, high-current pulse service, providing rapid switching of substantial stored energy in pulsed-power circuits.
Hot-cathode grid-controlled hydrogen thyratron for high-voltage, high-current pulse service.
Super Jumbo 4-pin bayonet
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Explicit equivalent designation on Toshiba 1G35P sheet.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Gas filling
Hydrogen
Starting anode voltage minimum
2500 V
Peak inverse anode voltage maximum
8000 V
Data set 02
Published operating points and test conditions from this source.
Maximum peak inverse anode voltage
2500 V
PulsingOrSwitching
Maximum peak cathode current
90 A
PulsingOrSwitching
Maximum average cathode current
100 mA
PulsingOrSwitching
Data set 03
Published operating points and test conditions from this source.
Peak forward anode voltage maximum
8000 V
HydrogenThyratron;Pulse
Peak anode current maximum
50 A
HydrogenThyratron;Pulse
Average anode current maximum
100 mA
HydrogenThyratron;Pulse
Pulse width maximum
2 µs
HydrogenThyratron;Pulse
Data set 04
Published operating points and test conditions from this source.
Device family
Hydrogen thyratron
Section1
Source reference
See chapter Tubes for Microwave Equipment in this volume
SourceCrossReference
Data set 05
Published operating points and test conditions from this source.
Peak Anode Current
90 A
Average Anode Current
100 mA
Minimum DC Supply Voltage
2500 V
Maximum Rate of Rise of Anode Current
1000 A/us
Pulse Repetition Rate
2500 pps
Pulse Duration
6 us
DC Anode Supply Voltage
4000 V
PulseModulator
Pulse Repetition Rate
2250 pps
PulseModulator
Pulse Width
0.5 us
PulseModulator
Peak Power Output
310 kW
PulseModulator
DC Anode Current
94 mA
PulseModulator
Data set 06
Published operating points and test conditions from this source.
Peak anode voltage
8 kV
Peak inverse anode voltage
8 kV
Peak anode current
90 A
Mean anode current
100 mA
Current rise rate
1000 A/us
Pulse duration
6 us
Minimum positive grid voltage
175 V
Inverse grid voltage max
200 V