Power - Triode (over 1000V 100W) ·Triode

4228A

Large water-cooled power triode for multi-kilowatt transmitter service. Approximately 5 kW plate dissipation and 6 kV plate capability support several kilowatts of published push-pull output in major transmitting equipment.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
22 V / 41 A

Description

The 4228A is a water-cooled triode described in the Standard Valves datasheet, using a directly heated filament cathode and published operating data.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
22 V
Nominal heater current
41 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
2200 Ω
Transconductance
0.00818 S
Amplification factor
18
Max plate voltage
6000 V
Max plate dissipation
5000 W
Max grid dissipation
100 W
Max cathode current
1.5 A

Explicit alternate/previous designation printed on 3Q150E datasheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1937 Standard Valves

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Total emission

    6 A

    Published datasheet value

  • Grid-anode capacitance

    24 pF

    Published datasheet value

  • Anode-filament capacitance

    3 pF

    Published datasheet value

  • Grid-filament capacitance

    25 pF

    Published datasheet value

Other

  • Maximum frequency for above ratings

    3 MHz

    Published datasheet value

Data set 02

1947 Standard Valves

Published operating points and test conditions from this source.

SECTION 1

Triode

Construction

  • Cooling method

    Water

Other

  • Push-pull power output

    3.75 kW

    PushPull

  • Maximum anode voltage for anode modulation

    4000 V