Data set 01
2026 Western Electric 400s
Published operating points and test conditions from this source.
RelayControlSwitch
Characteristic
Peak Anode Voltage
165 volts
Peak Anode Voltage ..... 165 volts
Average Cathode Current
4 milliamperes
Average Cathode Current . 4 40 milliamperes
Averaging Time
1 second
Averaging Time . 1 second
Ambient Temperature Limits
-55 centigrade
Ambient Temperature Limits . โ55 to 85 centigrade
Starter Breakdown Voltage*
67 volts
Starter Breakdown Voltage* . 67 75 89 volts
Starter Voltage Drop at
10 amperes
Starter Voltage Drop at 10 m:ll:amperes 52 60 74 volts
Anode Voltage Drop at
10 milliamperes
Anode Voltage Drop at 10 milliamperes. 66 75 W volts
Required Transfer Current at
130 microamperes
Required Transfer Current at 130 Anode Vo!ts (D C ) 50 . microamperes
Other
Peak Inverse Anode Current
1 milliampere
Peak Inverse Anode Current 1 milliampere