Data set 01
1937 Standard Valves
Published operating points and test conditions from this source.
Triode
Characteristics
Total emission
45 A
Grid-anode capacitance
61 pF
Anode-filament capacitance
15 pF
Grid-filament capacitance
45 pF
Other
Maximum direct anode current
11 A
Maximum frequency at full ratings
2 MHz
Maximum anode voltage at 22 MHz
15000 V
Frequency=22MHz
Direct anode voltage
14000 V
ClassB;AF;TwoTubes
Grid bias
-150 V
ClassB;AF;TwoTubes
Maximum output
100 kW