Data set 01
1937 Standard Valves
Published operating points and test conditions from this source.
Triode
Characteristics
Total Emission
45 A
Published specification
Other
Water Flow
22 gallons/min
Published specification
Maximum Direct Anode Current
11 A
Published specification
Maximum Frequency For Full Ratings
2 MHz
Published specification
Maximum Anode Voltage At 22 MHz
15000 V
Frequency=22MHz
Direct Anode Voltage
12500 V
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Grid Bias
-150 V
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Zero-Signal Anode Current Per Valve
1.3 A
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Maximum-Signal Anode Current Per Valve
6.5 A
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Anode Dissipation
36.6 kW
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Anode-to-Anode Load Resistance
1700 ohm
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Maximum Output Two Valves
90 kW
ClassB; AFAmplifierOrModulator; BalancedTwoValveCircuit
Direct Anode Voltage
17.5 kV
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=2MHz
Direct Anode Current
4.8 A
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=2MHz
Grid Bias
-400 V
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=2MHz
Power Output
25 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=2MHz
Anode Dissipation
59 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=2MHz
Direct Anode Voltage
15 kV
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=12MHz
Direct Anode Current
4.8 A
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=12MHz
Grid Bias
-300 V
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=12MHz
Power Output
22 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=12MHz
Anode Dissipation
50 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=12MHz
Direct Anode Voltage
12 kV
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=19MHz
Direct Anode Current
4.8 A
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=19MHz
Grid Bias
-250 V
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=19MHz
Power Output
17 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=19MHz
Anode Dissipation
40 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=19MHz
Direct Anode Voltage
10 kV
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=22MHz
Direct Anode Current
4.8 A
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=22MHz
Grid Bias
-150 V
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=22MHz
Power Output
12 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=22MHz
Anode Dissipation
36 kW
ClassB; Telephony; ModulatedCarrierAppliedToGrid; Frequency=22MHz
Direct Anode Voltage
12 kV
ClassC; Telephony; AnodeModulated; Frequency=2MHz
Direct Anode Current
5 A
ClassC; Telephony; AnodeModulated; Frequency=2MHz
Grid Bias
-600 V
ClassC; Telephony; AnodeModulated; Frequency=2MHz
Carrier Output
40 kW
ClassC; Telephony; AnodeModulated; Frequency=2MHz
Anode Dissipation
20 kW
ClassC; Telephony; AnodeModulated; Frequency=2MHz
Direct Anode Voltage
11 kV
ClassC; Telephony; AnodeModulated; Frequency=12MHz
Direct Anode Current
5 A
ClassC; Telephony; AnodeModulated; Frequency=12MHz
Grid Bias
-500 V
ClassC; Telephony; AnodeModulated; Frequency=12MHz
Carrier Output
35 kW
ClassC; Telephony; AnodeModulated; Frequency=12MHz
Anode Dissipation
20 kW
ClassC; Telephony; AnodeModulated; Frequency=12MHz
Direct Anode Voltage
10 kV
ClassC; Telephony; AnodeModulated; Frequency=19MHz
Direct Anode Current
5 A
ClassC; Telephony; AnodeModulated; Frequency=19MHz
Grid Bias
-450 V
ClassC; Telephony; AnodeModulated; Frequency=19MHz
Carrier Output
30 kW
ClassC; Telephony; AnodeModulated; Frequency=19MHz
Anode Dissipation
20 kW
ClassC; Telephony; AnodeModulated; Frequency=19MHz
Direct Anode Voltage
9 kV
ClassC; Telephony; AnodeModulated; Frequency=22MHz
Direct Anode Current
5 A
ClassC; Telephony; AnodeModulated; Frequency=22MHz
Grid Bias
-400 V
ClassC; Telephony; AnodeModulated; Frequency=22MHz
Carrier Output
20 kW
ClassC; Telephony; AnodeModulated; Frequency=22MHz
Anode Dissipation
25 kW
ClassC; Telephony; AnodeModulated; Frequency=22MHz
Direct Anode Voltage
17.5 kV
ClassC; Telegraphy; Unmodulated; Frequency=2MHz
Direct Anode Current
9.6 A
ClassC; Telegraphy; Unmodulated; Frequency=2MHz
Grid Bias Range
-800 to -600 V
ClassC; Telegraphy; Unmodulated; Frequency=2MHz
Carrier Output
100 kW
ClassC; Telegraphy; Unmodulated; Frequency=2MHz
Anode Dissipation
68 kW
ClassC; Telegraphy; Unmodulated; Frequency=2MHz
Direct Anode Voltage
15 kV
ClassC; Telegraphy; Unmodulated; Frequency=12MHz
Direct Anode Current
9.6 A
ClassC; Telegraphy; Unmodulated; Frequency=12MHz
Grid Bias Range
-700 to -500 V
ClassC; Telegraphy; Unmodulated; Frequency=12MHz
Carrier Output
88 kW
ClassC; Telegraphy; Unmodulated; Frequency=12MHz
Anode Dissipation
56 kW
ClassC; Telegraphy; Unmodulated; Frequency=12MHz
Direct Anode Voltage
12 kV
ClassC; Telegraphy; Unmodulated; Frequency=19MHz
Direct Anode Current
9.6 A
ClassC; Telegraphy; Unmodulated; Frequency=19MHz
Grid Bias Range
-600 to -450 V
ClassC; Telegraphy; Unmodulated; Frequency=19MHz
Carrier Output
68 kW
ClassC; Telegraphy; Unmodulated; Frequency=19MHz
Anode Dissipation
47 kW
ClassC; Telegraphy; Unmodulated; Frequency=19MHz
Direct Anode Voltage
10 kV
ClassC; Telegraphy; Unmodulated; Frequency=22MHz
Direct Anode Current
9.6 A
ClassC; Telegraphy; Unmodulated; Frequency=22MHz
Grid Bias Range
-550 to -400 V
ClassC; Telegraphy; Unmodulated; Frequency=22MHz
Carrier Output
48 kW
ClassC; Telegraphy; Unmodulated; Frequency=22MHz
Anode Dissipation
48 kW
ClassC; Telegraphy; Unmodulated; Frequency=22MHz
Capacitance
Grid-Anode Capacitance
51 pF
Published specification
Anode-Filament Capacitance
14 pF
Published specification
Grid-Filament Capacitance
40 pF
Published specification