Data set 01
1937 Standard Valves
Published operating points and test conditions from this source.
Rectifier
Other
Heating Period After Transport
15 min
Published specification
Recommended Ambient Temperature
10 to 50 degC
Published specification
Heating Time At Ambient 15C Or Above
30 s
Published specification
Heating Time At Ambient 10C To 15C
5 min
Published specification
Load Potential
2500 V
TypicalOperatingConditions; Circuit=2; NumberOfValves=2
Load Current
900 mA
TypicalOperatingConditions; Circuit=2; NumberOfValves=2
Load Potential
5000 V
TypicalOperatingConditions; Circuit=3; NumberOfValves=4
Load Current
900 mA
TypicalOperatingConditions; Circuit=3; NumberOfValves=4
Load Potential
3000 V
TypicalOperatingConditions; Circuit=4; NumberOfValves=3
Load Current
1.2 A
TypicalOperatingConditions; Circuit=4; NumberOfValves=3
Load Potential
3000 V
TypicalOperatingConditions; Circuit=5; NumberOfValves=6
Load Current
2.4 A
TypicalOperatingConditions; Circuit=5; NumberOfValves=6
Load Potential
6000 V
TypicalOperatingConditions; Circuit=6; NumberOfValves=6
Load Current
1.5 A
TypicalOperatingConditions; Circuit=6; NumberOfValves=6
Output Connection Requirement
Connect output circuit to midpoint of filament transformer
Published specification