Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3X2500F3

Forced-air-cooled external-anode medium-mu power triode for amplifier, oscillator, and modulator service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
7.5 V / 53 A

Description

The EIMAC 3X2500F3 is a forced-air-cooled external-anode medium-mu power triode for amplifier, oscillator, and modulator service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
7.5 V
Nominal heater current
53 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.02 S
Amplification factor
20
Max plate voltage
6000 V
Max plate dissipation
2500 W
Max grid dissipation
150 W
Max cathode current
2.5 A

Highest published CW/service maximums promoted; amplification factor is published as a range and retained in parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Frequency for Maximum Ratings

    30 MHz

  • Filament/Heater Current

    49 A to 54 A

  • Amplification Factor

    19 to 26

Other

  • Maximum DC Plate Current

    2.5 A

    Class-C FM/Telegraphy and Class-B maximum

  • Typical DC Plate Voltage

    4000 V

    Class-C FM/Telegraphy

  • Typical Plate Output Power

    7500 W

    Class-C FM/Telegraphy

  • FCC Carrier Power, Plate Modulated

    5000 W

    Published FCC rating

  • FCC Carrier Power, Grid-Modulated or Linear

    1250 W

    Published FCC rating

Capacitance

  • Grid-Plate Capacitance

    16.8-23.2 pF

    Published min-max

  • Grid-Filament Capacitance

    29.2-40.2 pF

    Published min-max

  • Plate-Filament Capacitance

    0.6-1.2 pF

    Published min-max

Data set 02

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Grid-Plate Capacitance

    20 pF

  • Grid-Filament Capacitance

    31 pF

  • Plate-Filament Capacitance

    1.5 pF

  • Transconductance

    0.02 A/V

  • Frequency Maximum

    30 MHz

  • Typical RF Output Power

    7500 W

  • FCC Plate-Modulated Carrier Rating

    5000 W

  • FCC Linear Carrier Rating

    1250 W