Data set 01
1962 Eimac
Published operating points and test conditions from this source.
Triode
Characteristic
Frequency for Maximum Ratings
30 MHz
Filament/Heater Current
49 A to 54 A
Amplification Factor
19 to 26
Other
Maximum DC Plate Current
2.5 A
Class-C FM/Telegraphy and Class-B maximum
Typical DC Plate Voltage
4000 V
Class-C FM/Telegraphy
Typical Plate Output Power
7500 W
Class-C FM/Telegraphy
FCC Carrier Power, Plate Modulated
5000 W
Published FCC rating
FCC Carrier Power, Grid-Modulated or Linear
1250 W
Published FCC rating
Capacitance
Grid-Plate Capacitance
16.8-23.2 pF
Published min-max
Grid-Filament Capacitance
29.2-40.2 pF
Published min-max
Plate-Filament Capacitance
0.6-1.2 pF
Published min-max