Data set 01
1962 Eimac
Published operating points and test conditions from this source.
Triode
Capacitance
Grid-Plate - - - - - o 5 o - 1.86 216 uuf
216 pF
Grid-Cathode - - - - - = - - 5.60 7.60 uuf
7.6 pF
Plate-Cathode - - - - - - - a o - 0.035 uuf
0.035 pF
Other
Maximum plate voltage
1000 V
Maximum plate/cathode current
125 mA
Maximum plate dissipation
100 W
Maximum grid dissipation
2 W