Data set 01
1946 Standard Telephone and Cables
Published operating points and test conditions from this source.
Thyratron
Other
Maximum peak inverse voltage
16000 V
Maximum peak anode current
50 A
Specialized - Thyratron ·Thyratron
Directly heated hot-cathode mercury-vapor thyratron for controlled high-voltage rectifier and switching circuits, corresponding to the 4080GA family.
Directly heated hot-cathode mercury-vapour thyratron for controlled high-voltage rectifier and switching circuits.
Special 3-contact base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Mercury-vapour thyratron; canonical SectionType fallback Other.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum peak inverse voltage
16000 V
Maximum peak anode current
50 A
Data set 02
Published operating points and test conditions from this source.
Filling
Mercury vapour
Filter type
Choke input
Supply frequency
50 Hz
Control method
Grid phase control