Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3J191E

Air-blast-cooled RF power triode for high-power transmitting service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 33 A

Description

Air-blast-cooled RF power triode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
33 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
3450 Ω
Amplification factor
26
Max plate voltage
10000 V
Max plate dissipation
5000 W
Max cathode current
2 A

Values transcribed from the approved datasheet; additional published data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1946 Standard Telephone and Cables

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Anode to grid

    12.5 pF

    Published direct interelectrode capacitance

  • Anode to filament

    2 pF

    Published direct interelectrode capacitance

  • Heater/filament nominal current

    33 A

    Nominal published value

Data set 02

1947 Standard Valves

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-anode capacitance

    12.5 pF

  • Grid-cathode/filament capacitance

    11 pF

  • Anode-cathode/filament capacitance

    2 pF

Other

  • Maximum frequency for published rating

    50 MHz

  • Cooling method

    Air blast