Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3CX6000H3

Highly reliable forced-air-cooled ceramic/metal power triode for amplifier and oscillator service. A rigid mesh filament is intended to improve longevity, while 6 kW plate dissipation supports roughly 9 kW RF output.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
5 V / 72 A

Description

The Svetlana™ 3CX6000H3 is a highly reliable ceramic/metal power triode designed for use in amplifier or oscillator service. A modern mesh filament is used, ensuring better mechanical rigidity and long lasting concentricity of the filament, contributing to longer life. Flexible leads connect to the filament terminals and a mounting flange provides the grid connection. The flange provides a convenient way to mount the tube. The Svetlana 3CX6000H3 is manufactured in the Svetlana Electron Devices complex in St. Petersburg, Russia. Characteristics Svetlana Outline drawing R Electrical Filament: Thoriated-tungsten mesh Voltage 5.0± 0.25 V A Current @ 5.0V 72 A B Anode Amplification factor (average) 22 Direct interelectrode capacitances, with filament grounded*: Input 50.0 pF Output 1.2 pF P F Grid Flange Feedback 30 pF J K Maximum usable frequency (CW) 90 MHz V (12 holes) Mechanical M Cooling Forced air

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
72 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
22
Max plate voltage
8000 V
Max plate dissipation
6000 W
Max grid dissipation
400 W

Promoted maximum ratings and characteristics from source; additional published values retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

199X Svetlana

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Voltage 5.0±

    0.25 V

    triode designed for use in amplifier or oscillator service. A modern

  • Current @

    5 V

    triode designed for use in amplifier or oscillator service. A modern

  • Input

    50 pF

    triode designed for use in amplifier or oscillator service. A modern

  • Output

    1.2 pF

    triode designed for use in amplifier or oscillator service. A modern

  • Feedback

    30 pF

    triode designed for use in amplifier or oscillator service. A modern

  • Maximum usable frequency (CW)

    90 MHz

    triode designed for use in amplifier or oscillator service. A modern

Other

  • DC plate voltage

    8000 V

    Maximum Ratings:

  • Plate dissipation

    6000 W

    Maximum Ratings:

  • Grid dissipation

    400 W

    Maximum Ratings:

  • DC grid voltage

    -550 V

    Maximum Ratings:

  • DC grid current

    450 mA

    Maximum Ratings:

  • Phone: 256 882 1344 Phone: 650 233

    429 V

    Maximum Ratings:

  • DC plate voltage

    8000 V

    Typical Operation, Grounded Cathode

  • DC plate current

    1.56 A

    Typical Operation, Grounded Cathode

  • DC grid voltage

    -400 V

    Typical Operation, Grounded Cathode

  • DC grid current

    290 mA

    Typical Operation, Grounded Cathode

  • Peak positive RF grid voltage

    765 V

    Typical Operation, Grounded Cathode

  • Plate input power

    12480 W

    Typical Operation, Grounded Cathode

  • Plate dissipation

    3480 W

    Typical Operation, Grounded Cathode

  • Plate output power

    9000 W

    Typical Operation, Grounded Cathode

  • 1 The cooling requirements above are based on

    50 ˚C

    Typical Operation, Grounded Cathode

  • temperature below

    200 ˚C

    Typical Operation, Grounded Cathode