Skip to main content

Specialized - Thyratron ·Thyratron

3C45W

Ruggedized hydrogen thyratron for high-power network-discharge pulse switching, with reservoir control for stable long-life operation.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / -

Description

The 3C45W is a ruggedized hydrogen-filled thyratron for network-discharge service, designed for high resistance to shock and vibration and equipped with a reservoir for stable long life.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
3000 V

Published maximum ratings and characteristics audited; remaining values retained densely in parameter table.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • The [1]

    3

    The 3C45W is a unipotential cathode, three element hydrogen See outline drawing

  • The [2]

    5

    The 3C45W is a unipotential cathode, three element hydrogen See outline drawing

  • such service, it is suitable for producing pulse outputs of

    55

    such service, it is suitable for producing pulse outputs of 55

  • KW at an average power level of more than

    65 kW

    KW at an average power level of more than 65 watts.

  • Max. peak anode voltage, forward

    3 V

    Max. peak anode voltage, forward.... 3.0 Kilovolts

  • Min. anode supply voltage

    300 V

    Min. anode supply voltage.............. 300 Volts d.c.

  • Max. peak anode current

    35 mA

    Max. peak anode current............... 35 Amperes

  • Electrical Data, General Nom. Min. Max. Max. average anode current

    45 mA

    Electrical Data, General Nom. Min. Max. Max. average anode current............ 45 Milliamperes

  • Heater voltage [1]

    63 V

    Heater voltage.......................... ... 63 59 6.7 Volts a.c. Mox. RMS anode current (Note 3)..... 1.25 Amperes a.c.

  • Heater voltage [2]

    59 V

    Heater voltage.......................... ... 63 59 6.7 Volts a.c. Mox. RMS anode current (Note 3)..... 1.25 Amperes a.c.

  • Heater voltage [3]

    6.7 V

    Heater voltage.......................... ... 63 59 6.7 Volts a.c. Mox. RMS anode current (Note 3)..... 1.25 Amperes a.c.

  • Heater voltage [4]

    3 V

    Heater voltage.......................... ... 63 59 6.7 Volts a.c. Mox. RMS anode current (Note 3)..... 1.25 Amperes a.c.

  • Heater voltage [5]

    1.25 V

    Heater voltage.......................... ... 63 59 6.7 Volts a.c. Mox. RMS anode current (Note 3)..... 1.25 Amperes a.c.

  • Heater current. E,== [1]

    6.3 mA

    Heater current. E,==6.3 volts...... 2.2 2.7 Amperes Max. epy x ib x prr.._.._...._. 0.3x 107

  • Heater current. E,== [2]

    2.2 mA

    Heater current. E,==6.3 volts...... 2.2 2.7 Amperes Max. epy x ib x prr.._.._...._. 0.3x 107

  • Heater current. E,== [3]

    2.7 mA

    Heater current. E,==6.3 volts...... 2.2 2.7 Amperes Max. epy x ib x prr.._.._...._. 0.3x 107

  • Heater current. E,== [4]

    0.3 mA

    Heater current. E,==6.3 volts...... 2.2 2.7 Amperes Max. epy x ib x prr.._.._...._. 0.3x 107

  • Heater current. E,== [5]

    107 mA

    Heater current. E,==6.3 volts...... 2.2 2.7 Amperes Max. epy x ib x prr.._.._...._. 0.3x 107

  • Minimum heating time......_........_ [1]

    3 mA

    Minimum heating time......_........_.. 3 Minutes Max. anode current rate of rise........ 750 Amperes/usecond

  • Minimum heating time......_........_ [2]

    750 mA

    Minimum heating time......_........_.. 3 Minutes Max. anode current rate of rise........ 750 Amperes/usecond

  • Peak trigger voltage....................... Note

    4 V

    Peak trigger voltage....................... Note 4

  • Mechanical Data, General Max. peak inverse trigger voltage

    200 V

    Mechanical Data, General Max. peak inverse trigger voltage.... 200 Volts

  • Any Max. anode delay time (Note [1]

    5

    .. Any Max. anode delay time (Note 5)....... 0.6 Microsecond

  • Any Max. anode delay time (Note [2]

    0.6

    .. Any Max. anode delay time (Note 5)....... 0.6 Microsecond

  • BOSE. . Per outline Max. anode delay time drift

    0.15

    BOSE. . Per outline Max. anode delay time drift.. ... 0.15 Microsecond

  • Net Weight [1]

    2.5

    Net Weight ... 2.5 Ounces Ambient temperature............_._.... —50° to - 90° Cent.

  • Net Weight [2]

    -50

    Net Weight ... 2.5 Ounces Ambient temperature............_._.... —50° to - 90° Cent.

  • Net Weight [3]

    90

    Net Weight ... 2.5 Ounces Ambient temperature............_._.... —50° to - 90° Cent.

  • Typical Operation as Pulse Modulator, Note

    4

    Typical Operation as Pulse Modulator, Note 4

  • Peak network voltage

    3 V

    Peak network voltage.................... 3.0 Kilovolts with the tube removed should have the following character-

  • Pulse repetition rate

    2500

    Pulse repetition rate....................... 2500 Pulses/secand istics:

  • Pulse length [1]

    0.5 V

    Pulse length............................ 0.5 Microsecond A. Voltage......cooooooe..... 175-250 Volts

  • Pulse length [2]

    175 V

    Pulse length............................ 0.5 Microsecond A. Voltage......cooooooe..... 175-250 Volts

  • Pulse length [3]

    -250 V

    Pulse length............................ 0.5 Microsecond A. Voltage......cooooooe..... 175-250 Volts

  • Pulse forming network impedance [1]

    45.2 us

    Pulse forming network impedance.... 45.2 Ohms 8. Duration 2 Microseconds (at 70% points)

  • Pulse forming network impedance [2]

    8 us

    Pulse forming network impedance.... 45.2 Ohms 8. Duration 2 Microseconds (at 70% points)

  • Pulse forming network impedance [3]

    2 us

    Pulse forming network impedance.... 45.2 Ohms 8. Duration 2 Microseconds (at 70% points)

  • Pulse forming network impedance [4]

    70 us

    Pulse forming network impedance.... 45.2 Ohms 8. Duration 2 Microseconds (at 70% points)

  • Trigger voltage [1]

    200 V

    Trigger voltage............................ 200 Volts C. Source of impedance.. 1500 Ohms (max.)

  • Trigger voltage [2]

    1500 V

    Trigger voltage............................ 200 Volts C. Source of impedance.. 1500 Ohms (max.)

  • Peak power output (Resistive load D. Rate of rise

    200 W

    Peak power output (Resistive load D. Rate of rise................ 200 Volts/microsecond (min.)

  • Peak anode current

    35 A

    Peak anode current ... 35 Amperes The limits of anode time delay and anode time jitter are based

  • Average anode current

    44 A

    Average anode current ... ... .044 Amperes d.c. on the minimum trigger. Using the highest permissible trigger

  • The time of anode delay is measured between the

    26

    The time of anode delay is measured between the 26 percent

  • Note

    2 V

    Note 2 point on the rising portion of the unloaded grid voltage pulse

  • The peak inverse voltage should not exceed

    1.5 kV

    The peak inverse voltage should not exceed 1.5 KV during and the point at which evidence of anode conduction first

  • The root mean square anode current shall be computed as the Note

    6 uA

    The root mean square anode current shall be computed as the Note 6

  • square root of the product of the peak current and the Time jitter is measured at the

    50 uA

    square root of the product of the peak current and the Time jitter is measured at the 50 percent point on the anode

  • Published value

    2

    2. CATHODE MIN.

  • Published value

    3

    3. GRID

  • Published value

    4

    4. HEATER & CATHODE