Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

367

Gas-filled double-anode rectifier for lead-acid battery chargers handling batteries up to about twelve cells. Rated for approximately 3 A DC output and 18 A peak current with a low forward voltage drop.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
-
Base pins
-
Nominal heater
1.9 V / 8 A

Description

Gas-filled double-anode rectifier for lead-acid battery chargers up to twelve cells.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
1.9 V
Nominal heater current
8 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
140 V
Rectifier nominal output current
3 A
Rectifier peak forward current
18 A
Rectifier forward voltage drop
8 V
Rectifier warm-up time
30 s

Published ratings/characteristics promoted from the approved source.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
140 V
Rectifier nominal output current
3 A
Rectifier peak forward current
18 A
Rectifier forward voltage drop
8 V
Rectifier warm-up time
30 s

Second physical rectifier section; electrical properties populated from the documented identical section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X Tesla

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • HeaterVoltageNominal

    18 V

    Nominal

  • HeaterCurrentNominal

    7 A

    Nominal

Data set 02

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filament heating time

    30 s

    IndustrialRectifier

  • Arc voltage drop

    8 V

    IndustrialRectifier

  • Ignition voltage

    18 V

    IndustrialRectifier

Other

  • Peak inverse anode voltage maximum

    140 V

    IndustrialRectifier

  • Average anode current maximum

    3 A

    IndustrialRectifier

  • Peak anode current maximum

    18 A

    IndustrialRectifier

  • Recommended temperature range

    -55 to +75 °C

    IndustrialRectifier

  • Transformer RMS voltage

    45 V

    CircuitA

  • DC output voltage

    26 V

    CircuitA

  • DC output current

    6 A

    CircuitA

SECTION 2

Rectifier

Characteristic

  • Filament heating time

    30 s

    IndustrialRectifier

  • Arc voltage drop

    8 V

    IndustrialRectifier

  • Ignition voltage

    18 V

    IndustrialRectifier

Data set 03

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Application: battery charger (

    6 A

    Application: battery charger (6 A per valve, max,12 Pb-

  • Application: chargeur d'accumulateurs (

    6 A

    Application: chargeur d'accumulateurs (6 A par tube,

  • Anwendung : Batterielader (

    6 A

    Anwendung : Batterielader (6 A pro R&hre, max, 12 Pb

SECTION 2

Rectifier

Other

  • Application: battery charger (

    6 A

    Application: battery charger (6 A per valve, max,12 Pb-

  • Application: chargeur d'accumulateurs (

    6 A

    Application: chargeur d'accumulateurs (6 A par tube,

  • Anwendung : Batterielader (

    6 A

    Anwendung : Batterielader (6 A pro R&hre, max, 12 Pb