Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

35Z6G

High-vacuum rectifier and voltage-doubler tube for AC/DC supplies. Rated for approximately 700 V peak inverse voltage and 110 mA DC output from a 35 V series-string heater.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
7O
Socket code
IO
Base pins
7
Nominal heater
35 V / 300 mA

Description

35Z6G is listed in the supplied receiving-tube handbook as a high-vacuum rectifier/doubler. The published heater/filament rating is 35.0 V at 0.3 A.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
7O
Socket code
IO
Base pins
7
Nominal heater voltage
35 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

7O - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max plate voltage
235 V
Rectifier peak inverse voltage
700 V
Rectifier nominal output current
110 mA
Rectifier peak forward current
660 mA
Rectifier forward voltage drop
20 V
Rectifier max heater-cathode voltage
350 V

Representative row for two electrically identical independent rectifier sections.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Max plate voltage
235 V
Rectifier peak inverse voltage
700 V
Rectifier nominal output current
110 mA
Rectifier peak forward current
660 mA
Rectifier forward voltage drop
20 V
Rectifier max heater-cathode voltage
350 V

Second physical rectifier section; electrical properties populated from the documented identical section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak inverse voltage

    700 V

    Published rectifier service

  • DC output current

    110 mA

    Published rectifier service

  • Peak current

    660 mA

    Published rectifier service

  • RMS supply voltage

    235 V

    Published rectifier service

Characteristic

  • Tube voltage drop

    20 V

    At 220 mA DC

  • Heater/filament voltage

    35 V

    Published heater/filament rating

  • Heater/filament current

    300 mA

    Published heater/filament rating

SECTION 2

Rectifier

Other

  • Peak inverse voltage

    700 V

    Published rectifier service

  • DC output current

    110 mA

    Published rectifier service

  • Peak current

    660 mA

    Published rectifier service

Data set 02

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • AC plate voltage per plate RMS

    117 V

    VoltageDoubler

  • DC output current

    110 mA

    VoltageDoubler

Characteristic

  • Tube voltage drop at 220 mA DC per plate

    20 V

SECTION 2

Rectifier

Other

  • AC plate voltage per plate RMS

    117 V

    VoltageDoubler

  • DC output current

    110 mA

    VoltageDoubler

Characteristic

  • Tube voltage drop at 220 mA DC per plate

    20 V