Data set 01
2026 Western Electric 300s
Published operating points and test conditions from this source.
RelayControlSwitch
Other
ForwardPeakAnodeVoltage
165 V
InversePeakAnodeVoltage
165 V
PeakForwardCathodeCurrent
40 mA
Characteristic
StarterBreakdownVoltage
80 V
Bogey; Min=67 V; Max=89 V
StarterVoltageDrop
65 V
10 mA; Bogey
Anode Voltage Drop
80 V
10 mA; Bogey
RequiredTransferCurrent
50 uA
130 V anode
DeionizationTimeMainGap
1 ms
Bogey
IonizationTimeStarterGap
0.05 ms