Skip to main content

Specialized - Thyratron ·Thyratron

323A

Western Electric argon/mercury special-purpose diode for high-current switching and rectifier service rather than a grid-controlled thyratron.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
UX4
Base pins
5
Nominal heater
2.5 V / 7 A

Description

Argon/mercury special-purpose diode for high-current switching/rectifier service.

Socket description

Medium-shell UX 4-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
UX4
Base pins
5
Nominal heater voltage
2.5 V
Nominal heater current
7 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max cathode current
1.5 A
Rectifier peak inverse voltage
500 V
Rectifier nominal output current
1.5 A
Rectifier peak forward current
6 A
Rectifier forward voltage drop
15 V
Rectifier warm-up time
10 s

Thyratron; published conduction ratings mapped to applicable rectifier-like fields.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1956 Western Electric Tubes

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristics

  • Gas filling

    Argon and mercury

Other

  • Maximum peak anode current

    6 A

Data set 02

2026 Western Electric 200s

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Maximum Time Averaging Anode Current

    5 s

  • Maximum Instantaneous Grid Current

    50 mA

  • Operating Temperature Minimum

    -20 C

  • Operating Temperature Maximum

    90 C

  • Nominal Deionization Time

    1000 us

Data set 03

2026 Western Electric 300s

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Maximum peak voltage between anode and grid

    500 V

  • Maximum instantaneous anode current

    6 A

  • Maximum average anode current

    1.5 A

  • Required heating time

    10 s

Characteristic

  • Approximate tube voltage drop

    15 V

    Conducting