Data set 01
1956 Western Electric Tubes
Published operating points and test conditions from this source.
Pentode
Application
Service
General-purpose voltage amplification
Voltage Pentode ·Pentode
Western Electric heater-cathode general-purpose pentode designed for voltage amplification.
General-purpose heater-cathode pentode for voltage amplification.
Octal 6-contact base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Promoted fields audited from printed ratings/characteristics; remaining published values preserved as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Service
General-purpose voltage amplification
Data set 02
Published operating points and test conditions from this source.
Control grid to plate
0.025 pF
Control grid to heater/cathode/screen/suppressor grids
6 pF
Plate to heater/cathode/screen/suppressor grids
15 pF
Maximum direct screen-grid current
2.5 mA
Typical plate current
5.6 mA
PlateVoltage=250V;ScreenGridVoltage=135V;ControlGridVoltage=-3V