Skip to main content

Power - Triode (over 1000V 100W) ·Triode

3073A

Single-ended water-cooled transmitting triode for high-power RF service, using a massive directly heated filament.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 54 A

Description

3073A is a single ended water cooled triode described in the Standard Valves datasheet. The source provides construction, electrical constants, limiting conditions, and operating information.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
54 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
17400 Ω
Amplification factor
40
Max plate voltage
7500 V
Max plate dissipation
2500 W
Max grid dissipation
200 W
Max cathode current
900 mA

Extracted semantically from complete approved datasheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1946 Standard Telephone and Cables

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Grid-anode capacitance

    9 pF

  • Anode-filament capacitance

    1.5 pF

  • Grid-filament capacitance

    7 pF

Other

  • Maximum frequency for full ratings

    50 MHz

  • Maximum anode voltage at 100 MHz

    5000 V

    Frequency=100MHz