Data set 01
1946 Standard Telephone and Cables
Published operating points and test conditions from this source.
Rectifier
Other
Supply frequency
50 Hz
ChokeInputFilter
Rectifier - Half Wave ·Rectifier
Indirectly heated mercury-vapor half-wave rectifier for high-voltage, high-current power conversion, combining approximately 20 kV inverse-voltage capability with ampere-class average current.
Half-wave mercury-vapour rectifier; indirectly heated.
Goliath industrial rectifier base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Mercury-vapour or high-voltage rectifier ratings promoted from the published maximum-ratings table.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Supply frequency
50 Hz
ChokeInputFilter
Data set 02
Published operating points and test conditions from this source.
Maximum DC Output Voltage
6400 V
ChokeInputFilter 50Hz Circuit2 2Valves
Maximum DC Output Current
2.5 A
ChokeInputFilter 50Hz Circuit2 2Valves
Maximum DC Output Voltage
13000 V
ChokeInputFilter 50Hz Circuit3 4Valves
Maximum DC Output Current
2.5 A
ChokeInputFilter 50Hz Circuit3 4Valves
Maximum DC Output Voltage
9500 V
ChokeInputFilter 50Hz Circuit4 3Valves
Maximum DC Output Current
3.75 A
ChokeInputFilter 50Hz Circuit4 3Valves
Maximum DC Output Voltage
9500 V
ChokeInputFilter 50Hz Circuit5 6Valves
Maximum DC Output Current
7.5 A
ChokeInputFilter 50Hz Circuit5 6Valves
Maximum DC Output Voltage
18500 V
ChokeInputFilter 50Hz Circuit6 6Valves
Maximum DC Output Current
3.75 A
ChokeInputFilter 50Hz Circuit6 6Valves
MercuryVapour
1
MinimumPreheatPeriodColdAmbient
30 min
AfterShipmentOrTransit