Data set 01
1946 Standard Telephone and Cables
Published operating points and test conditions from this source.
Rectifier
Other
Supply frequency
50 Hz
ChokeInputFilter
Rectifier - Half Wave ·Rectifier
Directly heated hot-cathode mercury-vapor rectifier for high-voltage supplies. Rated for approximately 10 kV peak inverse voltage, 250 mA DC output, and 1 A peak current.
Hot-cathode mercury-vapour rectifier.
Medium-shell UX 4-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Mercury-vapour or high-voltage rectifier ratings promoted from the published maximum-ratings table.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Supply frequency
50 Hz
ChokeInputFilter
Data set 02
Published operating points and test conditions from this source.
Maximum DC Output Voltage
3200 V
ChokeInputFilter 50Hz Circuit2 2Valves
Maximum DC Output Current
500 mA
ChokeInputFilter 50Hz Circuit2 2Valves
Maximum DC Output Voltage
6500 V
ChokeInputFilter 50Hz Circuit3 4Valves
Maximum DC Output Current
500 mA
ChokeInputFilter 50Hz Circuit3 4Valves
Maximum DC Output Voltage
4500 V
ChokeInputFilter 50Hz Circuit4 3Valves
Maximum DC Output Current
750 mA
ChokeInputFilter 50Hz Circuit4 3Valves
Maximum DC Output Voltage
4500 V
ChokeInputFilter 50Hz Circuit5 6Valves
Maximum DC Output Current
1.5 A
ChokeInputFilter 50Hz Circuit5 6Valves
Maximum DC Output Voltage
9500 V
ChokeInputFilter 50Hz Circuit6 6Valves
Maximum DC Output Current
750 mA
ChokeInputFilter 50Hz Circuit6 6Valves
MercuryVapour
1