Data set 01
1940 RCA
Published operating points and test conditions from this source.
Klystron
Other
__Freauency
4460 MHz
__Freauency: 3840 to 4460 Mc.
Voltage. . . « «
0.5 V
Voltage. . . « « . . 6.3+0.5, ... a or dc volts
Current
440 mA
Current. . . . . . . 0.44 ... ... amp,
Frequency Range
4460 MHz
Frequency Range. . . . 3840 to 4460 . . . . . . . . . Mc
DC RESONATOR VOLTAGE . . . . .+ .+ . «
330 V
DC RESONATOR VOLTAGE . . . . .+ .+ . « . . . 330 max. volts
Positive Value . . . . « v v v o o
0 V
Positive Value . . . . « v v v o o 4 .. 0 max. volts
Negative Value + v v « v o v v v v v v
400 V
Negative Value + v v « v o v v v v v v 400 max. volts
DC RESONATOR CURRENT « « . v v« v v v
37 mA
DC RESONATOR CURRENT « « . v v« v v v . 37 max. ma
Heater negative with respect to cathode
50 V
Heater negative with respect to cathode. 50 max. volts
Heater positive with respect to cathode
50
Heater positive with respect to cathode. 50 max. wvolts
Typical Operation © at
4150 MHz
Typical Operation © at 4150 Mc in Mode "A"
DC Resonator Voltage . . . . . . . PN
300 V
DC Resonator Voltage . . . . . . . PN 300 volts
DC Reflector Voltage Range*
-150 V
DC Reflector Voltage Range* . . . . .. -85 to -150 volts
DC Resonator Current
25 mA
DC Resonator Current . . . . . . . . .. 25 ma
Frequency Change®
35 MHz
Frequency Change® . . . . . . .. .. 35 Mc
© RESONATOR VOLT$=
300 V
© RESONATOR VOLT$=300
RESONATOR VOLTS=
300 V
RESONATOR VOLTS=300
RESONATOR VOLTS =
300 V
RESONATOR VOLTS =300