Data set 01
1940 RCA
Published operating points and test conditions from this source.
Magnetron
Other
Navelength of
10 cm
Navelength of 10 cm approx.
Voltage
1.8 V
Voltage 1.8 a-c or d-c volts
Current
2 A
Current 2.0 amp.
D-C Plate Voltage
0 V
D-C Plate Voltage 10 00 max. volts
D-C Stabilizing-Electrode Voltage
50 V
D-C Stabilizing-Electrode Voltage 7 50 max. volts
D-C Plate Current
5 mA
D-C Plate Current 5 max. ma.
D-C Stabilizing—-Electrode Current
13 mA
D-C Stabilizing—-Electrode Current 13 max. ma.
Typical Operation at
10 cm
Typical Operation at 10 cm approx.:
Filament Voltage *
1.8 V
Filament Voltage * 1.8 1.8 volts
D-C Plate Voltage
1000 V
D-C Plate Voltage 900 1000 volts
D-C Stabilizing-Electrode Voltage
50 V
D-C Stabilizing-Electrode Voltage 550 6 50 volts
D-C Plate Current
4 mA
D-C Plate Current 4 4 ma.
D-C Stabilizing-Electrode Current
10 mA
D-C Stabilizing-Electrode Current 6 10 ma.
Power Output (approx.)
1 W
Power Output (approx.) 0.9 1 watt