Skip to main content

Power - Triode ·Triode

2C39A

High-mu ceramic-metal UHF transmitting triode for amplification, oscillation, and pulse service into the microwave region. Approximately 100 W plate dissipation and high transconductance support useful RF power at frequencies extending into the gigahertz range.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
SPECIAL4
Base pins
-
Nominal heater
6.3 V / 1 A

Description

The RCA 2C39A is a forced-air-cooled uhf power triode. The supplied source provides transmitting, RF, or rectifier ratings appropriate to this device.

Socket description

Special 4-contact transmitting-tube base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
SPECIAL4
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.025 S
Amplification factor
100
Max plate voltage
1000 V
Max plate dissipation
100 W
Max grid dissipation
2 W
Max cathode current
125 mA

Promoted fields populated from published ratings/characteristics; additional published values retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 Eimac Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater Cu rrent

    1

    Heater Cu rrent 1.0 amperes

  • Grid -Cathode

    6.5

    Grid -Cathode 6.50

  • Pla te- Cathode [1]

    0

    Pla te- Cathode 0 .035

  • Pla te- Cathode [2]

    35

    Pla te- Cathode 0 .035

  • MAXIM UM RATIN G S D-C Plate Voltage

    900 V

    MAXIM UM RATIN G S D-C Plate Voltage - 900 Volts

  • D-C Cathode Cu rr ent

    90

    D-C Cathode Cu rr ent 90 Ma.

  • D-C PLATE VOLTAG E [1]

    1000

    D-C PLATE VOLTAG E - 1000 VO LTS - 22 Volts

  • D-C PLATE VOLTAG E [2]

    22

    D-C PLATE VOLTAG E - 1000 VO LTS - 22 Volts

  • D-C GRID VOLTAGE [1]

    -150 V

    D-C GRID VOLTAGE - -150 VOLTS 12 Wat ts

  • D-C GRID VOLTAGE [2]

    12 V

    D-C GRID VOLTAGE - -150 VOLTS 12 Wat ts

  • PEAK NEG ATIVE R-F G RID VOLTAGE

    400 V

    PEAK NEG ATIVE R-F G RID VOLTAGE - 400 VOLTS

  • PLATE DISSIPATIO N '

    100

    PLATE DISSIPATIO N ' 100 WATTS

  • D-C Plate Volta ge

    800

    D-C Plate Volta ge - 800 Volts ra dio fre qu e ncy rate . Usually suc h actio n

Data set 02

1956 RCA Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum Plate/Inverse Voltage

    600 V

    Source rating

  • Maximum Plate Dissipation

    100 W

Characteristics

  • Maximum Full-Input Frequency

    2500 MHz

  • Transconductance

    22000 uS

Data set 03

1958 Amperex Industrial

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate voltage

    800 V

    RFAmplifierOrOscillator; ClassC; Telegraphy

  • Plate current

    90 mA

    RFAmplifierOrOscillator; ClassC; Telegraphy

  • Grid voltage

    -40 V

    RFAmplifierOrOscillator; ClassC; Telegraphy

  • Grid current

    30 mA

    RFAmplifierOrOscillator; ClassC; Telegraphy

  • Maximum frequency at full input rating

    2500 MHz

Capacitance

  • Grid-to-plate capacitance

    2 pF

  • Grid-to-cathode capacitance

    6.6 pF

  • Plate-to-cathode capacitance

    0.035 pF

Data set 04

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater Current

    900 mA to 1.05 A

Capacitance

  • Grid-Cathode Capacitance

    5.6 to 7 pF

  • Grid-Plate Capacitance

    1.95 to 2.15 pF

  • Plate-Cathode Capacitance Maximum

    0.035 pF

Other

  • Frequency for Maximum Ratings

    2.5 GHz

  • Pulse Plate Voltage Maximum

    3500 V

    PlatePulsed

  • Pulse Plate Current Maximum

    3 A

    PlatePulsed

  • Pulse Cathode Current Maximum

    4.8 A

    PulseModulator

  • Typical CW Useful Output

    40 W

    Frequency=500MHz

Data set 05

1963 Siemens

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater voltage

    6.3 V

  • Heater current

    1.025 A

Data set 06

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • The Eimac [1]

    2

    The Eimac 2C39A is a ceramic-metal high-mu planai. triode with a plate-

  • The Eimac [2]

    9

    The Eimac 2C39A is a ceramic-metal high-mu planai. triode with a plate-

  • frequency multiplier at frequencies to above

    2500 MHz

    frequency multiplier at frequencies to above 2500 megacycles. The new ceramic-metal

  • at seal temperatures up to

    250

    at seal temperatures up to 250°C, and longer life expectancy than its glass pi.ototypes.

  • deliver [1]

    27 W

    deliver 27 watts useful power output with 6 watts driving powei.. As an r-f oscillator

  • deliver [2]

    6 W

    deliver 27 watts useful power output with 6 watts driving powei.. As an r-f oscillator

  • at [1]

    2500 MHz

    at 2500 megacycles the 2C39A will deliver a minimum of 12 watts useful power output.

  • at [2]

    2 MHz

    at 2500 megacycles the 2C39A will deliver a minimum of 12 watts useful power output.

  • at [3]

    9 MHz

    at 2500 megacycles the 2C39A will deliver a minimum of 12 watts useful power output.

  • at [4]

    12 MHz

    at 2500 megacycles the 2C39A will deliver a minimum of 12 watts useful power output.

  • Heater: Jot:::neg(T!:eeHipp|i-ca+io;sn)

    6.3

    Heater: Jot:::neg(T!:eeHipp|i-ca+io;sn) : : : : : - - 6.3 yol's

  • Current [1]

    -950 mA

    Current--------- -0.95 I.10 amperes

  • Current [2]

    10 A

    Current--------- -0.95 I.10 amperes

Data set 07

1971 Machlette Laboratories

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • frequency multiplier, or power amplifier in radio trans- is forced-air cooled and is capable of dissipating

    100 W

    frequency multiplier, or power amplifier in radio trans- is forced-air cooled and is capable of dissipating 100 watts.

  • mitting service from low frequency to above

    2500 MHz

    mitting service from low frequency to above 2500 Mc.

  • Heater Voltage

    6.3 V

    Heater Voltage ... ............................ 6.3 Voltst

  • Heater Current ac [1]

    6.3 V

    Heater Current ac 6.3 Volts ... ..... 1.0 Amps

  • Heater Current ac [2]

    1 V

    Heater Current ac 6.3 Volts ... ..... 1.0 Amps

  • Heater Heating Time, minimum (Before Applying Plate Voltage)

    60 s

    Heater Heating Time, minimum (Before Applying Plate Voltage) ... 60 Seconds

  • Amplification Factor

    100

    Amplification Factor ... ... 100

  • Maximum Incoming Air Temperature

    45 mA

    Maximum Incoming Air Temperature .... 45 °C

  • Maximum Anode Temperature ... e

    175 mA

    Maximum Anode Temperature ... e 175 °C

  • D-C Plate Voltage . T

    1000 V

    D-C Plate Voltage . T . 1000 wvolts

  • D-C Grid Voltage

    150 V

    D-C Grid Voltage ... 150 volts Maximum Ratings, Absolute Values

  • D-C Cathode Current . L [1]

    125 V

    D-C Cathode Current . L 125 mA D-C Plate Voltage* . ... .. ... 600 volts

  • D-C Cathode Current . L [2]

    600 V

    D-C Cathode Current . L 125 mA D-C Plate Voltage* . ... .. ... 600 volts

Data set 08

1975 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater Current Range

    900 mA to 1.05 A

  • Cathode Heating Time

    60 s

Capacitance

  • Input Capacitance

    6.3 pF

  • Output Capacitance

    0.035 pF

  • Grid-Plate Capacitance

    1.98 pF

Other

  • Frequency Maximum

    3 GHz

  • Pulse Plate Voltage Maximum

    3500 V

    PlatePulsed

  • Pulse Current Maximum

    4.8 A

    PulseModulator

  • Pulse Duration Maximum

    6 us

  • Duty Factor Maximum

    0.0033

  • Grid-Pulsed Plate Voltage Maximum

    1000 V

  • Plate-Pulsed Peak Plate Voltage Maximum

    3500 V

  • Pulse Plate Current Maximum

    3 A

Data set 09

1976 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater Current Range

    900 mA to 1.05 A

  • Cathode Heating Time

    60 s

Capacitance

  • Input Capacitance

    6.3 pF

  • Output Capacitance

    0.035 pF

  • Grid-Plate Capacitance

    1.98 pF

Other

  • Frequency Maximum

    3 GHz

  • Pulse Plate Voltage Maximum

    3500 V

    PlatePulsed

  • Pulse Current Maximum

    4.8 A

    PulseModulator

  • Pulse Duration Maximum

    6 us

  • Duty Factor Maximum

    0.0033

  • Grid-Pulsed Plate Voltage Maximum

    1000 V

  • Plate-Pulsed Peak Plate Voltage Maximum

    3500 V

  • Pulse Plate Current Maximum

    3 A

Data set 10

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Cathode current Ix = max

    125 mA

    Cathode current Ix = max. 125 mA

  • Anode voltage V, = max

    1000 V

    Anode voltage V, = max. 1000 V

  • Anode dissipation W, = max

    100 W

    Anode dissipation W, = max. 100 W

  • Grid dissipation Wy = max

    2 W

    Grid dissipation Wy = max. 2 W

Characteristic

  • Mutual conductance S

    25 mA

    Mutual conductance S = 25 mA/V

  • Output power Wy

    18 W

    Output power Wy = 18 W

  • Heater voltage Vi

    6.3 V

    Heater voltage Vi = 6.3 V

  • Heater current Ir = 0.95tol

    1 A

    Heater current Ir = 0.95tol.1 A

  • For pulsed operation,

    6.3 V

    . For pulsed operation, 6.3 V is normally required for preheating. For C.W.

  • Anode to grid Cag > 1.86 <

    2.16 pF

    Anode to grid Cag > 1.86 < 2.16 pF

  • Anode to cathode Cak <

    0.035 pF

    Anode to cathode Cak < 0.035 pF

  • Grid to cathode Cgk > 5.6 <

    7.6 pF

    Grid to cathode Cgk > 5.6 < 7.6 pF