AEI photoelectric device documented with manufacturer ratings and characteristics. The available source establishes optical detection service, but the extracted description does not expose enough construction detail to classify it more narrowly than a general phototube.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
11
Nominal heater
-

Description

27M13 PhotoTube; full semantic REDO from printed ratings and characteristics.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
11
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 0

Photomultiplier

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

REDO promoted-field audit

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 AEI Industrial Valves

Published operating points and test conditions from this source.

SECTION 0

Photomultiplier

Characteristics

  • Maximum dynode-chain voltage

    700 V

  • Maximum anode-to-last-dynode voltage

    125 V

  • Maximum anode current

    1 mA

  • Average photocathode sensitivity

    20 uA/lumen

  • Typical anode-to-last-dynode voltage

    50 V

  • Typical voltage per stage

    125 V

  • Maximum anode dark current

    0.25 uA

  • Luminous sensitivity

    2.5 A/lumen

  • Average current amplification

    125000

Data set 02

1961 Associated Electrical Industries

Published operating points and test conditions from this source.

SECTION 0

Photomultiplier

Other

  • MaximumDynodeChainVoltage

    900 V

  • MaximumAnodeToLastDynodeVoltage

    125 V

  • TypicalAnodeToLastDynodeVoltage

    50 V

  • TypicalVoltagePerStage

    125 V

  • LuminousSensitivityPerAnode

    2.5 A/lm

  • AverageCurrentAmplificationPerAnode

    125000

Characteristic

  • AveragePhotocathodeSensitivity

    20 nA/lm

    TungstenLamp2700K

  • MaximumAnodeDarkCurrentPerAnode

    0.25 uA