Current
0.07
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 1 -Grid No.1 — published value 1
1
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 1 -Grid No.1 — published value 2
4
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 2 -Grid No. 3, — published value 1
2
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 2 -Grid No. 3, — published value 2
3
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 2 -Grid No. 3, — published value 3
5
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
internal Shield ~`
6
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 3 -Heater — published value 1
3
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pin 3 -Heater — published value 2
7
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Plate Voltage — published value 1
26.5 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Plate Voltage — published value 2
250 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 1
26.5 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 2
100 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
From a grid-No.l resistor of
2 Mohm
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Plate Resistance (Approx ) — published value 1
0.25 Mohm
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Plate Resistance (Approx ) — published value 2
1 Mohm
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Transconductance — published value 1
2000
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Transconductance — published value 2
4000
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
transconductance of 40 µmhos — published value 1
40 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
transconductance of 40 µmhos — published value 2
25 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
transconductance of 20 µmhos — published value 1
20 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
transconductance of 20 µmhos — published value 2
8 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Plate Current — published value 1
1.7 mA
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Plate Current — published value 2
10.5 mA
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid—No.2 Current — published value 1
0.7 mA
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid—No.2 Current — published value 2
4 mA
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
PLATE ~Ib~OR GRID-N~2~IC2~MILLIAMPERES
2 mA
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
HEATER VOLTS=PLATE VOLTS=GRID-N4 2 VOLTS=26.5 — published value 1
2 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
HEATER VOLTS=PLATE VOLTS=GRID-N4 2 VOLTS=26.5 — published value 2
26.5 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
PL ATE(Ib) OR GRID -N°2 (I~z) MILLIAMPERES
2 mA
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
~: GRID-NI'2 VOLTS=100 — published value 1
2 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
~: GRID-NI'2 VOLTS=100 — published value 2
100 V
Published datasheet value; multiple numbers on one source row represent separate limits or operating conditions.