Skip to main content

Tube cross-reference

25L6GT alternatives, equivalents, and replacements

Review exact electrical variations and directional substitutions recorded for the 25L6GT power - beam (not sweep). Compare core specifications and verify every restriction before using a replacement.

Exact variations of 25L6GT

These designations belong to the same electrical variation group. Their names may differ because of international standards, manufacturing tolerances, or materials, but they are recorded as electrically equivalent—not merely substitutes.

  • 25W6GT

    Power - TV Vertical Output

    Base
    7AC
    Socket
    IO
    Base pins
    7
    Sections
    1
    Heater voltage
    25 V
    Heater current
    0.3 A

Replacement tubes for 25L6GT

The following tubes are recorded as possible replacements for 25L6GT. This direction does not establish that 25L6GT can replace them.

6046

Power - Beam (NOT sweep)

Receiving To Industrial Tubes

The database records 6046 as a possible replacement for25L6GT.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typePower - Beam (NOT sweep)Power - Beam (NOT sweep)
ConstructionBeamPowerBeamPower
BaseB7-77AC
SocketIOB7G
Base pins77
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A
25L6

Power - Beam (NOT sweep)

Receiving Tubes

The database records 25L6 as a possible replacement for25L6GT.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typePower - Beam (NOT sweep)Power - Beam (NOT sweep)
ConstructionBeamPowerBeamPower
BaseB7-77AC
SocketIOIO
Base pins7Not recorded
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A
25L6G

Power - Beam (NOT sweep)

Receiving Tubes

The database records 25L6G as a possible replacement for25L6GT.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typePower - Beam (NOT sweep)Power - Beam (NOT sweep)
ConstructionBeamPowerBeamPower
BaseB7-7Not recorded
SocketIOIO
Base pins7Not recorded
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A
25W6GT

Power - TV Vertical Output

Receiving Tubes

The database records 25W6GT as a possible replacement for25L6GT.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typePower - Beam (NOT sweep)Power - TV Vertical Output
ConstructionBeamPowerBeamPower
BaseB7-77AC
SocketIOIO
Base pins77
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A

Where 25L6GT can be used as the replacement

In these recorded relationships, 25L6GT is the replacement tube. The listed original tubes are not automatically suitable as replacements for 25L6GT.

25L6

Power - Beam (NOT sweep)

Receiving Tubes

The database records 25L6GT as a possible replacement for25L6.

No special restrictions are recorded for this substitution.

Specification25L6GT replacementOriginal tube
Tube typePower - Beam (NOT sweep)Power - Beam (NOT sweep)
ConstructionBeamPowerBeamPower
BaseB7-77AC
SocketIOIO
Base pins7Not recorded
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A
25L6G

Power - Beam (NOT sweep)

Receiving Tubes

The database records 25L6GT as a possible replacement for25L6G.

No special restrictions are recorded for this substitution.

Specification25L6GT replacementOriginal tube
Tube typePower - Beam (NOT sweep)Power - Beam (NOT sweep)
ConstructionBeamPowerBeamPower
BaseB7-7Not recorded
SocketIOIO
Base pins7Not recorded
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A
25W6GT

Power - TV Vertical Output

Receiving Tubes

The database records 25L6GT as a possible replacement for25W6GT.

No special restrictions are recorded for this substitution.

Specification25L6GT replacementOriginal tube
Tube typePower - Beam (NOT sweep)Power - TV Vertical Output
ConstructionBeamPowerBeamPower
BaseB7-77AC
SocketIOIO
Base pins77
Sections11
Heater voltage25 V25 V
Heater current0.3 A0.3 A

Verify before substituting

Matching a base or heater voltage is not enough to prove that two tubes are interchangeable. Check pin connections, heater current, maximum ratings, bias requirements, warm-up behavior, and the equipment manufacturer’s service documentation before making a substitution.

View the complete 25L6GT specifications →